    zhuroy's Avatar
    zhuroy Posts: 6, Reputation: 1
    New Member
     
    #1

    Aug 18, 2009, 05:38 PM
    T-start fan on/furnace blower on, AC w/fan on/auto, blower off
    If no cool or heat, just fan on, there has blower start in furnace;

    While in air conditioner, regardless fan on or auto, there will be no indoor blower on at all;

    While outside condenser and its fan seems fine.

    I lready jump wires G, RC and Y in T-start, won't see any difference.

    By the way, yesterday it suddentely worked for a minutes or 2 before it is completely dead after I lower the temprature.

    Thanks for your advice
    Roy
    wmproop's Avatar
    wmproop Posts: 3,749, Reputation: 91
    Ultra Member
     
    #2

    Aug 18, 2009, 08:46 PM
    Since we don`t know the name or model number of your airhandler/furnace all the answers you receive will be guesses but you might,just might have a bad fan control and again not knowing what you have I don`t know how to tell you if you have a separate control or if its bult into your circuit board or even if you have a circuit board
    zhuroy's Avatar
    zhuroy Posts: 6, Reputation: 1
    New Member
     
    #3

    Aug 18, 2009, 08:50 PM
    Quote Originally Posted by wmproop View Post
    since we don`t know the name or model number of your airhandler/furnace all the answers you recieve will be guesses but you might,just might have a bad fan control and again not knowing what you have I don`t know how to tell you if you have a seperate control or if its bult into your circuit board or even if you have a circuit board
    Thanks for the quick response

    The gas furnace: Lennox G24M 3/4-100A-7
    SN:6398B17474

    It has circuit bord.
    zhuroy's Avatar
    zhuroy Posts: 6, Reputation: 1
    New Member
     
    #4

    Aug 19, 2009, 04:59 AM

    A bit confused:

    1) fan is on when cool and heat off, does that mean indoor blower moto and its capacitor good?

    2) do I need to jump wires G, RC and Y in furnace circuit board to try?

    Tks
    zhuroy's Avatar
    zhuroy Posts: 6, Reputation: 1
    New Member
     
    #5

    Aug 19, 2009, 05:21 AM

    Just confirmed anther thing -
    If T-stat fan in on position, heat in on position, or heat and cool off, furnace blower will start; only switch T-start to cool, when outside condenser is started, the furnace blower will be immediately stopped.
    bonnie53's Avatar
    bonnie53 Posts: 4, Reputation: 1
    New Member
     
    #6

    Aug 24, 2009, 08:39 PM
    My air conditioner will not blow cold air. The unit outside is not running. We had the artic air guy out. Replaced compressor, and fuses and breaker. Worked great for 2 months now the unit outside is not working while air is blowing in the inside. Any ideas what can be wrong
    bonnie53's Avatar
    bonnie53 Posts: 4, Reputation: 1
    New Member
     
    #7

    Aug 24, 2009, 08:40 PM
    My air conditioner will not blow cold air. The unit outside is not running. We had the artic air guy out. Replaced compressor, and fuses and breaker. Worked great for 2 months now the unit outside is not working while air is blowing in the inside. Any ideas what can be wrong[/QUOTE]
    bonnie53's Avatar
    bonnie53 Posts: 4, Reputation: 1
    New Member
     
    #8

    Aug 24, 2009, 08:43 PM

    My air conditioner will not blow cold air. The unit outside is not running. We had the artic air guy out. Replaced compressor, and fuses and breaker. Worked great for 2 months now the unit outside is not working while air is blowing in the inside. Any ideas what can be wrong. I HAVE A LENOX HS26 SERIES 3 TONS
    wmproop's Avatar
    wmproop Posts: 3,749, Reputation: 91
    Ultra Member
     
    #9

    Aug 25, 2009, 06:19 PM
    bonnie53,, you need to start a thread of your own,
    Getting in on someone else's thread will not get you any responses,, sorry

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Furnace blower can not auto start [ 29 Answers ]

I have a problem with my furnace blower not starting automatically. It works good when I swiched the fan option to "ON", the furnace was burning and fan was running. However if I pick "AUTO", only the furnace burns periodicaly, and the fan totall gets stuck. I am wondering if it is a wiring...

Furnace ignites but blower won't start till furnace shuts down. [ 7 Answers ]

(Nordyne/Miller G3RA)-I have a furnace HSI(glow plug) that will ignite and burn until it gets too hot and shuts down. As soon as the furnace shuts down the blower starts to circulate air. The blower circulating air cools the furnace and it reignites.Shortly after the furnace ignites the blower...

Blower won't run in auto for heat with oil furnace [ 9 Answers ]

I have an oil furnace. A/C works fine. Heat last season worked fine. Started up furnace this year just fine. But blower would not start on auto. The blower will run in heat mode when set to On. I replaced the Limit Switch in the Plenum. No change.

AC , Furnace, and Blower not turning on w/ thermostat set to Auto or On. [ 20 Answers ]

Here's my issue. I cannot turn on either my AC, Furnace, or Blower from the thermostat. However, I can turn on the blower by manually pressing a 'Manual On' button inside the furnace. - AC is powered and was working a couple days ago. - Furnace was also working a couple days ago. - Found...