Ask Experts Questions for FREE Help !
Ask
    appu30's Avatar
    appu30 Posts: 2, Reputation: 1
    New Member
     
    #1

    Mar 21, 2006, 11:58 AM
    Rplacing Weathertron thermostat with White Rodgers
    Hello,
    I have a heat pump with auxiliary electric heat controlled by a Trane
    Weathertron thermostat. I am attempting to upgrade the thermostat with a programmable White -Rodgers(1F85-277)heat pump thermostat.I want to verify the correct wiring hookup for White-Rodgers
    Thermostat to the current unit.

    The current hookup for the Weathertron controller is:

    Terminal "F" (color-none) Purpose-Not used,
    Terminal "B" (color-Blue) purpose-24 volt common
    Terminal "X2" (color-Black) Purpose-Emergency heat?
    Terminal "W" (color-White) purpose-First stage Aux. Heat,
    Terminal "T" (color-Tan 0 purpose- Outdoor Thermistor,
    Terminal "G" (color-Green)purpose-Fan,
    Terminal "O" (color-Orange) purpose-Reversing valve,
    Terminal "Y"(color-yellow) purpose-First stage compressor,
    Terminal "R" (color-Red) purpose-24 volt hot

    Please click on the following link for referenced terminal connections in the White-Rodgers(1F85-277) manual.

    http://www.white-rodgers.com/pdfs/in.../0037-6560.pdf

    Regards!
    Appu30
    labman's Avatar
    labman Posts: 10,580, Reputation: 551
    Uber Member
     
    #2

    Mar 21, 2006, 05:23 PM
    I lack experience with heat pumps, but it looks good to me. I others provided as much information in their question as you.
    tkrussell's Avatar
    tkrussell Posts: 9,659, Reputation: 725
    Uber Member
     
    #3

    Mar 21, 2006, 05:47 PM
    I added the correct terminals that the wires should connect to below:


    Terminal "F" (color-none) Purpose-Not used,
    Terminal "B" (color-Blue) purpose-24 volt common C
    Terminal "X2" (color-Black) Purpose-Emergency heat? EW1
    Terminal "W" (color-White) purpose-First stage Aux. Heat, W2
    Terminal "T" (color-Tan 0 purpose- Outdoor Thermistor NOT USED
    Terminal "G" (color-Green)purpose-Fan,
    Terminal "O" (color-Orange) purpose-Reversing valve,
    Terminal "Y"(color-yellow) purpose-First stage compressor Y1
    Terminal "R" (color-Red) purpose-24 volt hot

    And I must say, nice job with the information and research!
    appu30's Avatar
    appu30 Posts: 2, Reputation: 1
    New Member
     
    #4

    Mar 22, 2006, 07:31 AM
    Thanks! I really appreciate your help, this came out very close what I thought.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search


Check out some similar questions!

Need Wiring help for a White-Rodgers Thermostat [ 2 Answers ]

I have 2 wire (red & White) heat only system. It is steam heat run by gas. Currently I have Honeywell thermostat which uses 3 AA batteries. Thermostat has R, RC, O, W, Y, G terminals. R and RC terminals are connected by a jumper cable. I have Red wire connected to terminal R and white wire...

White-Rodgers thermostat... What does this mean? [ 2 Answers ]

Okay, I'm about to smash this thing up. I fell asleep with the AC turned off earlier and now I wake up and its 77 degrees in here and I'm sweating. So I go turn the AC unit back on, setting it on 75 degrees to start with because I know you aren't supposed to do more than 2 degrees at a time....

White-Rodgers to new Hunter Thermostat (Wiring Help Please) [ 4 Answers ]

Hello, I have a new home, built in 2003, with Central Heat and Air. It's all run off electricity and is using a Lennox Model CB29M-41-1P heat pump. The WHITE ROGERS DIGITAL HEAT PUMP THERMOSTAT 1F89-211 used the following wires: White Red Brown Orange Yellow

White-Rodgers 50A50 -288 Wiring [ 1 Answers ]

I have a white-rodgers controller for my furnace/airconditioner, it has a white-rodgers mercury thermostat. Is there a wiring diagram I can follow to re-connect the thermostat? Does it also show where to terminate the coil wires for my condenser? Thank you Todd

Weathertron BAYSTAT240 [ 1 Answers ]

I am replacing a Weathertron thermostat BAYSTAT240; 3AAT80B1A1 with a Honeywell CT70A. The wiring identification are different. Is there a schematic anywhere to show the Weathertron wiring to letter code? Booz3