Ask Experts Questions for FREE Help !
Ask
    merle staten's Avatar
    merle staten Posts: 1, Reputation: 1
    New Member
     
    #1

    Dec 14, 2009, 11:51 AM
    Rheem furnace trouble shooting guide
    Burner comes on and then chuts off as soon as the fan comes on has anyone seen this before and what can I try
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Dec 14, 2009, 01:14 PM
    I think you better call a on site professional since usually when that happens it is because the heat exchanger has a hole in it. I would rather have you be safe then try to guess what else it could be.
    tinner2002's Avatar
    tinner2002 Posts: 8, Reputation: -1
    New Member
     
    #3

    Nov 17, 2011, 08:57 PM
    Sounds like it could be a bad proving switch for the indoor fan motor. When the board doesn't get a signal from the air switch, it assumes that the fan never came on. The board cuts off the gas automatically as a safety.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Trouble shooting Rheem hot water heater [ 13 Answers ]

How do I figure out what part is wrong with my Rheem Power Vent S/N 1094 D22371: which is powered by the RobertShawcontrols. The water heater won't turn on the gas to heat it up. I think it's the Ingition Control Justiceair

Concord furnace trouble shooting [ 4 Answers ]

My concord furnace blower works but the burner will not ignite,after a few seconds the blower shuts off.

Trouble shooting furnace [ 3 Answers ]

Hello I have a Altra 90 SX Armstrong furnace that has a cycle problem. The model # is a GUK75D103A with a Heatcraft control board 404030001 Cat. # 70K98 The problem that I'm actually having is that it is going through its cycles OK, except the induced fan keeps running and won't shut off. ...

Furnace Trouble shooting [ 1 Answers ]

I have an Coleman Evcon Furnace. Model #15020A the problem is I replaced the Inducer motor, and The furnace starts like normal but then the flames goes out after about a minute or two. The LED light says the Pressure switch is stuck open but it seems fine. I tried to replace the PC board but can't...

Trouble shooting GMP Furnace [ 1 Answers ]

I have a gmp075-4 gas fired furnace, I just replaced the gas valve and the thing starts up fine but when the burner fires and the hot bar goes out the burner goes out any ideas? Limit switch maybe ?