    Rheem Criterion II - blower works OK with heat or AC, not by itself
    The problem appears to be in the internal wiring or control board.

    Symptom: If I temporarily connect the red low voltage control wire from the transformer to the green control wire for the fan, a relay clicks on the control board. But the blower does not come on.

    I have tried re-seating all five of the blower wire connections to the circuit board but this didn't help.

    Does anyone have any suggestions? I'm just a homeowner, not an HVAC specialist. I'm positive the problem is not in the stat or any of the five wires from the stat to the Rheem. Thanks in advance for any thoughts.
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Jul 12, 2009, 06:49 PM
    Could be a bad relay, or motor. If it is the relay and it is mounted to the circuit board you will be replacing the board more than likely. Start by seeing if you have voltage at the circuit board the check the rest of the system for the proper voltages. There should be a wiring diagram on the back of the furnace door. Note the furnace door has to be installed if the unit has a furnace blower door safety switch.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Heat blower works ac blower won't shut off. [ 1 Answers ]

Hello, I am having trouble with my RTH230B Honeywell. I have a Gas furnace and an outdoor ac unit hooked up to a blower and the blower has a heat off cool setting on a switch on it. Our when set on heat everything works as it should. BUT as soon as I turn the blower to cool it turns on and...

Rheem Criterion II does not heat warmer than 67 degrees [ 1 Answers ]

My girlfriend has a Rheem Criterion II. The unit does not heat her home warmer than 67 degrees. I replaced the thermostat on the wall but no change. Is there something I should clean, tighten, check before I call in an expensive repair tech?

Heat,Rheem Furnace blower not working [ 6 Answers ]

HELLO, JUST CAME HOME IN NJ TO FIND HEAT NOT WORKING. FURNACE IS A RHEEM CLASSIC 90, MODEL#rcba-3765gg21x1. Have power to unit, breaker is on, when I depress covers interlock switch, LEDs light briefly & I can hear what sounds like a burner starting. Blower does not come on. Verified Thermostat...

Rheem Criterion II--heat cycle works, then shuts down [ 2 Answers ]

Hi- I'm having a problem with my gas furnace and don't know where to start to find out what it might be. When the thermostat calls for heat, the draft inducer kicks on, the ignitor glows, the gas starts and burns for a short time and then shuts off. It tries this whole cycle again, with the same...

Rheem Criterion II blower won't stop [ 4 Answers ]

I have a Rheem furnace and the low speed fan continues to stay on after the furnace has cycled off. When I disconnect the red wire (low speed wire), the furnace runs normally. I would imagine the switch for the low speed is open. Is the switch controlled by the IFC? Does the IFC need to be...


View more questions Search