    I have a Heil gas furnace. It is a high efficiency type built in 1983. When I went to change the thermostat from cool (summer mode) to heat (winter mode) the furnace came on but only blew cold air. I went to the unit and pulled the cover panel off. I saw that there was no combustion flame. The combustion air blower was on but no flame. To trouble shoot, I replaced the furnace filter, checked the discharge pipe to make sure it was not plugged, and then pulled the vacuum line off the combustion air blower. I slightly sucked on tube going to the vacuum switch and the pilot ignited and gas came on with full flame. As soon as I sopped applying suchion to the vacuum switch the flame went out.
    Does this mean I have a bad vacuum switch or could it be something else. I even sucked on the line, got flame pinched the line and the unit ran through a complete cycle until the upper heat exchanger sensor told it to shut down flame.
    Grady White's Avatar
    Grady White Posts: 1,417, Reputation: 59
    Ultra Member
     
    #2

    Sep 21, 2012, 06:26 PM
    The chances of a bad switch are slim indeed. That switch is a safety device to prevent firing if there is no draft. When you switched to heat, did the combustion blower come on? If it did, take a paper cliip or something similar & push through the nipple where the hose connects. Clogging in a common problem.
    davewhiteford's Avatar
    davewhiteford Posts: 3, Reputation: 1
    New Member
     
    #3

    Sep 23, 2012, 06:27 PM
    I did that to no avail. Just don't know what could be causing this issue. When I switched from cool to heat the combustion blower came on and the unit just pushed cold air when the main blower came on. That is when I went to check it out and tried sucking on the vacuum switch which ignited the burner as it should. I then put a paper clip in the orface of the fan where hose attaches and felt some resistance but it went through. Then reconected the hose and still the burner would not fire. I just don't want to go out and buy a combustion air blower or vacuum switch if that is not the problem.
    Grady White's Avatar
    Grady White Posts: 1,417, Reputation: 59
    Ultra Member
     
    #4

    Sep 23, 2012, 07:51 PM
    So much for the most common problem.
    Next, I suggest you take the vent system apart & check for blockages. One thing to particularly look for is any sag in the vent system which could trap water.
    You could disconnect the vent at the furnace & try for ignition. DO NOT ALLOW THE BURNER TO RUN MORE THAN A VERY FEW SECONDS.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

I have a goodman GDT090-4A gas furnace. The igniter will ignite the gas and the gas w [ 2 Answers ]

The igniter will ignite the gas, and the gas will run for a second or a few seconds and will then cut off. It will continue to cycle like this until it finally will stay on but at times will take forever.

My carrier gas furnace would not light up the pilot burner although sparks and gas is [ 0 Answers ]

My carrier gas furnace would not light up the pilot burner although sparks and gas is present. I've tried to light up the pilot burner with a gas grill light and it works.

I have a Frigidaire gas furnace which fires up for a couple of seconds then gas shuts [ 1 Answers ]

My Frigidaire gas furnace has 3 burners that ignite for a couple of seconds then shuts off. The electric ignition and fan works fine, it's just the burners that turns off after a few seconds. If I try turning the furnace on and off a few times it sometimes fires up and stays on. I have tried...

I have a Frigidaire gas furnace which fires up for a couple of seconds then gas shuts [ 0 Answers ]

My Frigidaire gas furnace has 3 burners that ignite for a couple of seconds then shuts off. The electric ignition and fan works fine, it just the burners that turns off. If I try turning the furnace on and off a few times it sometimes fires up and stays on.


View more questions Search