Old Sep 16, 2007, 09:09 PM
pwkelly
New Member
pwkelly is offline
 
Join Date: Sep 2007
Posts: 1
pwkelly See this member's comment history on his/her Profile page.
Replacement Furnace Blower Motor

Hi,

I have an older (~40 years, the original with the house) Coleman furnace. The blower motor (General Electric, 1/6 hp, 110 V, 60 Hz, 3.6 amps, PH 1, 1725 rpm) burnt out the other morning. I went to the local shop (RONA) to find a replacement and they didn't have the exact motor. Instead, the fellow working in the furnace department recommended a replacement GE motor (1/3 hp, 6.6 amps, 115V, 60Hz, PH 1, 1725 rpm). My question is will the furnance be able to handle the higher voltage and amps of the new motor, or will it damage the existing circuitry and wiring?

Thanks - Patrick

Reply With Quote
 
     

Answers
 
 
Old Sep 16, 2007, 09:21 PM   #2  
Heating & Air Conditioning Expert
hvac1000 is offline
 
hvac1000's Avatar
 
Join Date: Aug 2005
Location: Ohio
Posts: 11,308
hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.
There are 1/4 hp motors available. You can probably use the 1/3 it only draws 6.6 amps but you probably do not have a Amprobe to check the current draw after it is installed. That is why I recommend the 1/4 HP unit.
  Reply With Quote
 
     
 
 
Old Sep 16, 2007, 10:21 PM   #3  
Über Member
labman is offline
 
Join Date: Feb 2003
Location: Northern US
Posts: 10,646
labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.
I am sure the furnace is wired up with at least #14 if not #12 wire which is good for about twice the rated amps. The voltage is determined by your incoming power. The new motor will draw the amps needed for the load, about the same as the old.
  Reply With Quote
 
     
 
 
Old Sep 17, 2007, 02:50 AM   #4  
Heating & Air Conditioning Expert
hvac1000 is offline
 
hvac1000's Avatar
 
Join Date: Aug 2005
Location: Ohio
Posts: 11,308
hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.
He has what I believe to be a 1725 RPM single speed motor. When you go from a 1/6th to a 1/3 motor it does not mean that the motor will draw the same current because the new 1/3 hp motor has 3 or 4 speeds available. What speed is he going to pick that is equal to the 1/6 th HP motor because the slowest speed on the 1/3 HP replacement motor is usually rated 1/6 but that speed may not be powerful enough to do the job since it will be running at a lower speed than the original fixed speed 1725 RPM unit. Work load is work load but you still have to pick a speed.That is why I added the Amprobe statement and he probably does not have one to use to test. As far a the circuit from the breaker panel to the furnace you are absolutely correct in the fact that it is a 14 or 20 amp circuit but we are not concerned with that circuit. We have no idea what the wire size is going to the blower that is in the furnace. That is why I am more comfortable recommending a 1/4 hp since it is just one step above the original rate of the motor and not two steps. With a 1/4 HP motor it is close enough to the 1/6th that he could just wire it up at the highest speed with out a problem.
  Reply With Quote
 
     
 
 
Old Sep 17, 2007, 08:51 AM   #5  
Über Member
labman is offline
 
Join Date: Feb 2003
Location: Northern US
Posts: 10,646
labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.
The blower needs to turn at the same speed as before without a recheck of the temperature rise. A lower speed could mess up the efficiency of the furnace or lead to overheating. Likely it would be better to use a slower speed and a larger pulley, but the easiest and surest thing would be to just bolt in the new motor and connect it up to run at 1725.
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
furnace blower motor
(3 replies)
replacement blower motor wiring
(1 replies)
Furnace Blower Motor
(8 replies)
furnace blower motor
(1 replies)
Furnace Blower Motor replacement
(3 replies)

Search this Thread

Advanced Search

Bookmarks

Sponsors



Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 07:33 PM.