Ask Experts Questions for FREE Help !
Ask
    donbunker900's Avatar
    donbunker900 Posts: 5, Reputation: 1
    New Member
     
    #1

    Nov 30, 2007, 09:23 PM
    Proper side clearance on heat pump unit
    I recently had a brand new Rheem 4 ton/13SEER heat pump system installed in a new house. The outside unit (compressor) is set on a concrete pad in a corner so that the side clearance is 12" on one long side, 6" on the short side, and open to the outside on the other long side. The 4th side is a solid access panel. I mentioned to the installer that it looked a little close on the 6" side, and he said it was no big deal. Also the unit has about a 2" slope from side to side... so it is not level. He also said this was close enough..? I asked for the condenser paperwork and he said it was inside the unit..? At any rate, I need some re-assurance that the clearance and out of level condenser will be OK. I don't want to buy another one for a long time. Thanks! Donbunker
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Nov 30, 2007, 11:13 PM
    Get to the paperwork for exact factory clearence requirements. Many units are different so make sure to check yours under the correct model on the paperwork.The install instructions should be left with the customer when the job is done so could be he did leave them inside the unit. If not I would contact a responsible party at the company and demand your papers because you paid for them since they came with your unit.

    BTW units are to be close to level. Drainage is built in at the factory.
    KISS's Avatar
    KISS Posts: 12,510, Reputation: 839
    Uber Member
     
    #3

    Nov 30, 2007, 11:26 PM
    An install manual is located here:

    Achiever by Ruud 4 Ton 13 Seer Variable Speed Air Conditioning System with Heat Pump :: Air Conditioning/Heat Pump :: AC Direct, Inc.

    Page 7 has some distances. The 6" distance MIGHT be OK. Capacity will be lost if under 12". 4" is minimum.


    Page 9 says: Ensure it is level.

    The compressor will not get the proper lubercation if it isn't.

    This may not be your model.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

BUZZ on the outside unit of my A/C (heat pump) [ 5 Answers ]

The A/C of my heat pump is still working fine... but suddenly the outside unit started having this BUZZ when the unit is running. Everything seems to be working fine, the house is cool and the unit cycles nicely. Should I do something to prevent failure in the future? Thanks

Heat pump condensing unit will not shut off [ 4 Answers ]

My heat pump condensing unit has been running for several hours now without shutting off. It is blowing out cool air. When I turn unit off manually and turn back on, you can feel the heat for a few minutes and then it goes back to cool. Please help...

Can I disable outside unit with a heat pump? [ 4 Answers ]

I believe I have a Payne heat pump, and it only blows slightly warm air and when the unit comes on, it turns on the outside unit. I always thought the outside unit went with the air conditioner, but I'm learning that isn't always the case. I just installed a new thermostat, and didn't connect...

Heat Pump High Pres on LP Side [ 2 Answers ]

I have some a/c exp, recent purchased older home that has 4 HP's. One OK, one has stuck compressor,5ton, but what's stuping me is the other 2Ton Carrier units? Both I vacumn to 25+ in", started charge, they go to over 200psi in suction side, rev valve OK, can someone explain? Problem, Thanks ...

RUUD Heat Pump Outside Unit Fan not coming on [ 1 Answers ]

I just closed on my house - made one payment and the outside heat pump is not working!! About 3-4 weeks ago the fan on the outdside unit just sounded a little rough, almost a slight grind/knocking noise- although nothing major or too out of the ordinary for a fan motor ,just a little bit...


View more questions Search