    Pressure relief valve on new water heater leaks.
    I had a new water heater installed recently. Since the installation, the pressure relief valve has been leaking. The installer tested the house water pressure and said it was too high. I just had a new house water pressure regulator installed @ an even lower water pressure than before. The old water heater has never leaked prior to the new one being installed. I don't know what the pressure was before but I now have it set @ 56 PSI. And that is less that what I had before. Is it possible the pressure relief valve on the heater is faulty? How can I check the water heater pressure ?
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Jan 29, 2008, 04:38 PM
    Valve could be defective
    OR
    A back flow prevention/check valve was installed with your new Water heater
    OR
    You need to add a expansion tank in the cold water line between the backflow valve and the water heater. These tanks give the extra water a place to go.

    Do a Google on your problem to see what the items above do to correct your problem.
    tsa7man's Avatar
    tsa7man Posts: 154, Reputation: 9
    Junior Member
     
    #3

    Jan 29, 2008, 04:42 PM
    You stated that you have a new pressure regulator, and most have a check valve in them. If you don't have an expansion tank on the cold water feed side of the water heater, the hot water expands and it has no place to go... but to start lifting the pressure relief valve off it's seat and it starts seeping water. This is real common with the new water meters that most cities are now installing... you can go to many of the better HVAC / plumbing wholesalers and ask for a tattle-tale water heater drain pressure gage. Just screw it on your drain valve, open the valve to see your tank pressure, then set the red needle to the current pressure. As the pressure increases over a time... the black needle will move the red pointer to the highest pressure found in the tank during that time frame.
    tsa7man's Avatar
    tsa7man Posts: 154, Reputation: 9
    Junior Member
     
    #4

    Jan 29, 2008, 04:47 PM
    As well, you can go to the following web site Gas detectors | Thermal Imaging Cameras the have water pressure gages that I have described above... great site, I purchase a lot of my inspection / testing gear there.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Surging water pressure & leaking water heater relief valve [ 19 Answers ]

Just recently the pressure of our water in the house surges when we turn a faucet on, and the city water company verified that our pressure in the house when we open a faucet is higher than the pressure in the lines in the street, and after the water runs is at a normal pressure (meaning their...

30 Gallon Hot Water Heater Relief Valve ? [ 13 Answers ]

I just had the relief (release?) valve replaced on my Hot Water Heater because it was constantly leaking and dripping. The new one seems to work great because I don't see it dripping anymore. However, I kept a bucket under it to be cautious, and every day there is a little over a cup of clean water...

Hot Water Heater pressure relief valve [ 2 Answers ]

On my water heater, I have the Pressure Relief Valve on top. There is also a (plugged) PRV outlet on the side of the heater. Can I move my valve to the side outlet? Is there a reason that it may have been installed at the top as opposed to the side? Thanks

Lwater heater pressure relief valve [ 2 Answers ]

Relief valve leaks sometimes causing small flood, unit is rheem 50 gal gas fired unit. Thermostat is set at the mid setting, water tempurature is not exessive. Should I change the relief valve

Pressure relief valve / water heater [ 2 Answers ]

I have a leaking valve on my waterheater , do I need to replace pressure valve , if so what is correct way of doing so ?


View more questions Search