Quote:
| Originally Posted by aznwho its just a regular thermocouple. it was kinda loose on the pilot flame end so i adjusted it and now the thermocouple sits better in the flame. seems to be working well for now. again thanks for all your help. now I can sleep nice and warm. =)
also if you dont mind can i ask you a couple more questions?
i wanna know if the pilot flame is supposed to stay on even when i shut the gas valve off, because i shut it off before for like 20 seconds and the pilot flame was still on.
If it supposed to stay on can I just blow it out because I may change the thermocouple if the problem reoccurs. |
Your system is not 100% safety shutoff. That means if you just shut off the main gas valve it may not turn off the pilot. Follow the pilot tube back to where it connects for its gas supply. usually there is a very small finger shut off valve there to kill the pilot gas. One way or the other there has to be a way to turn the pilot gas off just look around and you will find it.
BY just blowing out the pilot flame is not a good idea. It will just allow the pilot gas to accumulate in the furnace and when you go to relite the pilot it might go BOOM. LOL
Note I mentioned before that a 100% shut off system is available. In the future you might consider changing it over for better safety.