Ask Experts Questions for FREE Help !
Ask
    v2030's Avatar
    v2030 Posts: 4, Reputation: 1
    New Member
     
    #1

    Jun 7, 2007, 05:45 AM
    Outside AC unit will not turn on.
    Here we go... Texas heat and AC problem...
    The out side unit will not turn on! I bypassed the Thermostat and connected the Y to R wire and the blower turns on , but the outside unit does not come on at all, I have checked the breaker, and have turned it off and back on, but same problem... is there any fuse in the unit itself that might have blown?
    Any help is greatly appreciated.:o
    CaptainRich's Avatar
    CaptainRich Posts: 4,492, Reputation: 537
    Cars & Trucks Expert
     
    #2

    Jun 7, 2007, 06:21 AM
    Are you referring to the fan or the compressor? Is the circuit breaker tripped? If it is you may have seized compressor (just went through that, myself) I'd like more info...
    v2030's Avatar
    v2030 Posts: 4, Reputation: 1
    New Member
     
    #3

    Jun 7, 2007, 07:31 AM
    If I set the thermostat to below the room temperature the fan which is set in auto mode will start working, but if I go outside and look the AC unit, it is dead... neither the fan or the compressor work! I have turned the breaker for the unit ON, OFF... but nothing happened. I am trying to find out if there might be a fuse between the breaker and the compressor/fan..

    Thanks
    letmetellu's Avatar
    letmetellu Posts: 3,151, Reputation: 317
    Ultra Member
     
    #4

    Jun 7, 2007, 09:30 AM
    Have a friend or someone help you with this. You stand outside at the unit and have the friend turn the thermostat to cool, see if you hear a loud click when it is turned on, if you do that means that the 24 volt power is getting to the contactor and the contactor is closing. Now you need to look for another Box that might control your unit, there may be one on the wall right beside your unit or it could be by where the furnace is but it sounds like you are not getting the 240 volt power to the unit.

    Let us know what you have tried and what did not work...

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Fan blade on my unit won't turn [ 8 Answers ]

My fan blade on my central unit won't turn. It appears it is trying to turn, so I helped it with a screw driver. The fan blade then runs with out fail, but will not cool. I was told that it might be my capacitor? Why is it when the blade turns it won't blow cold air?

A/c unit outside won't turn on byitself, thermastat? [ 6 Answers ]

My family went on a trip to see relatives in the country. When we came back the a/c had quit. The inside blower motor works, just the outside unit will not turn on. Everything is fairly new, except for the thermastat on the wall, which is one of those old round mercury like switches. I took the...

Outside unit won't turn on [ 1 Answers ]

My outside unit Ruud 10 seer won't come on. I looked closely and noticed that some of the thermostat wireing had been cut most likely by digging dogs. Anyway I have a yellow blue white red and green wires leading from the house but only yellow purple blue and brown at the unit which wires connect...

Unit does not turn on at all... [ 4 Answers ]

Help me please, I get power to all lines, wires, breaker boxes etc... but when I turn on both heat or air conditioner I get nothing at all. I tried replacing the thermostat and that did not fix the problem. I went outside to the condenser unit and took off the panel and pressed the contactor and...


View more questions Search