Old Mar 18, 2007, 04:01 PM
hurrikane
New Member
hurrikane is offline
 
Join Date: Feb 2007
Posts: 1
hurrikane See this member's comment history on his/her Profile page.
Outdoor fan on heat pump runs

The fan on an outdoor carrier unit won't turn off.
turned off at thermostate, tried everything, had to turn it off at the breaker.

I am thinking maybe a relay is stuck. Is this a part I can pick up and replace myself or is it a different problem all together

Thanks

Reply With Quote
 
     

Answers
 
 
Old Mar 19, 2007, 09:09 PM   #2  
HVACxpert
New Member
HVACxpert is offline
 
Join Date: Mar 2007
Posts: 13
HVACxpert See this member's comment history on his/her Profile page.
Sounds like a thermostat wire issue. If using a round mercury style thermostat and subbase with the heat off cool switches and some other type of equipment that turns the air handler fan on like a woodburner or something of that nature it will back feed thru the g terminal to the y terminal on the thermostat subbase in turn kicking on central air unit. Easy fix would be to replace thermostat with electronic type. Most have separate relays to keep from back feeding. Recommend Honeywell pro5000 or pro6000.
Have fun!
  Reply With Quote
 
     
 
 
Old Mar 20, 2007, 01:30 PM   #3  
NorthernHeat
Heating & Air Conditioning Expert
NorthernHeat is offline
 
Join Date: Oct 2006
Location: IN
Posts: 1,355
NorthernHeat See this member's comment history on his/her Profile page.NorthernHeat See this member's comment history on his/her Profile page.
The fan on most heat pumps are controled by a printed circiut board, if just the fan and not the compressor is running the board is probably the problem. If both are running it is a contactor.
  Reply With Quote
 
     


Question Tools Search this Question
Search this Question:

Advanced Search
Display Modes

 
Similar Sponsors

Similar Questions
Question Asker Topic Answers Last Post
Heat Pump Fan does not run at all times Sarge23 Heating & Air Conditioning 2 Jan 21, 2007 06:23 AM
Programmable Thermostat, Fan runs, Heat/Air do not run in Auto setting elbee Heating & Air Conditioning 10 Dec 4, 2006 04:53 PM
Water Heat Vent Fan runs constantly VIN442 Heating & Air Conditioning 5 Nov 7, 2006 03:13 PM
Heat Pump compressor fan problem dontkillbill Heating & Air Conditioning 1 Jul 20, 2006 02:35 PM
Heat pump AHU fan runs continuously barker7 Heating & Air Conditioning 0 Jul 3, 2006 06:47 AM




Copyright ©2003 - 2007, Ask Me Help Desk.
All times are GMT -8. The time now is 08:57 PM.

Content Relevant URLs by vBSEO 3.0.0 RC6 © 2006, Crawlability, Inc.