    Older Sears Kennmore gas furnace
    I have an older Sears Kennmore furnace, I'm guessing early 80's. Model # 867.763334 Furnace works great but intermittently does not work. When not working, only when I turn the power off and back on to the furnace will it work. Happens 3 times a week. Any ideas?
    NorthernHeat's Avatar
    NorthernHeat Posts: 1,455, Reputation: 132
    Ultra Member
     
    #2

    Dec 8, 2006, 10:43 AM
    The furnace is locking out, there are many causes on why they will do this. Also Sears doesn't make any furnaces, see if you can find who did, there should be another manufacturers number, Like NUGK-100 would tell me it is a Tempstar, they made many of Sears furnaces. There should be a diagnostic light that flash's a code when the lock out occurs, see if you can find the number of flashes or the codes. Could simply be a dirty flame sensor. Does it have a pilot light? Is it always on? Does it light the pilot each ignition sequence with an electri spark, or a glowing ignitor?
    wjglampe's Avatar
    wjglampe Posts: 4, Reputation: 1
    New Member
     
    #3

    Dec 8, 2006, 02:54 PM
    Quote Originally Posted by NorthernHeat
    The furnace is locking out, there are many causes on why they will do this. Also Sears doesn't make any furnaces, see if you can find who did, there should be another manufacturers number, Like NUGK-100 would tell me it is a Tempstar, they made many of Sears furnaces. There should be a diagnostic light that flash's a code when the lock out occurs, see if you can find the number of flashes or the codes. Could simply be a dirty flame sensor. Does it have a pilot light? Is it always on? Does it light the pilot each ignition sequence with an electri spark, or a glowing ignitor?
    Everything on the manuals I have call it a Sears furnace. Model #867.763334 "pilot free gas-fired space saver furnaces" I can't find any lights on the circuit board panel. NO pilot light. A control box "direct spark igniter module". Also a fan limit control that is a box with a dial on it with temp ranges that looks like an old choke spring on a car. Any info is appreciated.
    NorthernHeat's Avatar
    NorthernHeat Posts: 1,455, Reputation: 132
    Ultra Member
     
    #4

    Dec 8, 2006, 04:02 PM
    Look at the plate inside the furnace, not the owners manual. It will usually have that sears number and more. Is it 80 or 90 percent efficient? Clean the flame sensor, if it is direct spark ignition there will be metal rods in front of the burners, one is for ignition the other is the flame sensor.
    wjglampe's Avatar
    wjglampe Posts: 4, Reputation: 1
    New Member
     
    #5

    Dec 10, 2006, 05:57 PM
    Quote Originally Posted by NorthernHeat
    look at the plate inside the furnace, not the owners manual. It will usually have that sears number and more. Is it 80 or 90 percent efficient? Clean the flame sensor, if it is direct spark ignition there will be metal rods infront of the burners, one is for ignition the other is the flame sensor.
    I found the MFG Model #, SUGB105AG01. I can't find who the actual manufacturer is.
    You are right, the furnace goes into lockout mode. I can turn the thermostat down all the way for 1 minute and then turn it back up, the furnace kicks in. I'm going to try cleaning the flame sensor. Any other suggestions?
    NorthernHeat's Avatar
    NorthernHeat Posts: 1,455, Reputation: 132
    Ultra Member
     
    #6

    Dec 11, 2006, 04:18 PM
    Is it 90%?
    wjglampe's Avatar
    wjglampe Posts: 4, Reputation: 1
    New Member
     
    #7

    Dec 11, 2006, 08:00 PM
    Quote Originally Posted by NorthernHeat
    Is it 90%?
    I have been all over that thing and I can't see where it says 80% or 90%. Built in 1978 though! The thing works great! I cleaned the flame sensor today, we'll see after a few days if that was the culprit.
    whiskey22's Avatar
    whiskey22 Posts: 1, Reputation: 1
    New Member
     
    #8

    Jan 27, 2012, 08:10 PM
    I need a wire diagram for a sears 10 model # 867-763730

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Gas furnace [ 2 Answers ]

For the past 2 nights my furnace has been blowing out cold air. I have a furnace which is equipped with an ignition device which automatically lights the piolet. I did everything from cutting off the gas valve and power to furnace. When I restarted everything back up, the furnace came on but no air...

Wiring for older lennox furnace [ 2 Answers ]

I have an older Lennox furnace that had some wires melted in a flash fire. Does anyone know where I might get the wiring schematics to rewire the unit? When I went to move the wires they broke apart and know I want to ensure that they are connected properly again. The model is G8R-120-1, serial...

Sears Kenmore Elite Gas Dryer mod.110.70092991 [ 6 Answers ]

My 3-yr.old Kenmore Elite Gas dryer has been doing very odd things! After running a load, when the dryer shuts off, or I shut it off (clear it), the touch control panel goes dead. No lights are lit. If you push the touch pad for various cycles it will not do anything. You can also push...

Need sears gas dryer wiring schematic [ 1 Answers ]

Hello people. Does anyone on here have a wiring diagram for a sears mod. # 11073912100 gas dryer? I'd be happy for any sears gas dryer diagram just to gain the basic wiring/function of the various controls. Thanks in advance.

Gas furnace [ 14 Answers ]

Igot a 1972 carrer furnace it catches fire at the spud part of burner I got 11.5 inch watter column preasure on line you can cut it off turn it back on and it burns good blaze looks good I need some comet on air ajustment or what might be causing this I have cleaned the burners , thanks.


View more questions Search