Question
 
 
#1  
Old Dec 20, 2006, 05:25 PM
Morrowrj's Avatar
Morrowrj
Full Member
Morrowrj is offline
 
Join Date: Dec 2006
Location: Pittsburgh, Pa
Posts: 308
Morrowrj See this member's comment history on his/her Profile page.
Oil furnace, Burner cuts out

Ok, my original post was over a noisy draft regulator. Since then i have determined the cause of the regulator banging was the burner going out. This only occurs for a fraction of a second, just little pulses. I changed my in-line fuel filter and my burner nozzle. When i remove the inspection cover i can see this occur. My question is where to look at next. should i suspect a dying fuel pump ? Or could this be the result of contaminates in the fuel tank ? Has anyone seen anything like this occur >? And, yes, there is over 500 gal in the tank. Unit is Thermo-Pride OH-5. approx 11 yrs.

Reply With Quote
 
     

Answers
 
 
Old Dec 20, 2006, 07:50 PM   #2  
Über Member
labman is offline
 
Join Date: Feb 2003
Location: Northern US
Posts: 10,646
labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.
Go over the suction line to the pump very carefully. The tiniest leak could result in the pump drawing air. More so if the line comes out the top of tank.

Water doesn't burn very well. Could your oil be contaminated?
  Reply With Quote
 
     
 
 
Old Dec 22, 2006, 07:20 PM   #3  
Full Member
Morrowrj is offline
 
Morrowrj's Avatar
 
Join Date: Dec 2006
Location: Pittsburgh, Pa
Posts: 308
Morrowrj See this member's comment history on his/her Profile page.
Hmm, thats a tall order as my tank is buried outside. I did check it with water finding paste and it was a negative.
  Reply With Quote
 
     
 
 
Old Dec 22, 2006, 08:06 PM   #4  
Über Member
labman is offline
 
Join Date: Feb 2003
Location: Northern US
Posts: 10,646
labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.
Hummmm! Perhaps rig up a small supply of known good oil near the furnace. It that doesn't stop the problem, then you will know it is not the tank or line. Keeping much fuel near the furnace isn't a good idea, but a little for a test should be OK.

Comments on this post
Morrowrj agrees: Now why didnt I think of that ....
  Reply With Quote
 
     
 
 
Old Dec 29, 2006, 06:33 PM   #5  
Full Member
Morrowrj is offline
 
Morrowrj's Avatar
 
Join Date: Dec 2006
Location: Pittsburgh, Pa
Posts: 308
Morrowrj See this member's comment history on his/her Profile page.
Well, just as a follow up. I performed Labmans recommended test and the burner ran perfectly. This led me to believe i had air getting into the line. However i decided to recheck my inline filter (one month old) and it was plugged !! It turns out i had microbacteria(black slime) growing in my fuel tank. A quick treatment of this agent FPPF and i am back in business. Thanks for the help in solving this puzzler. Maybe this will help someone else as well.
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login



Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes
Ask your question or search...



Similar Threads
Carrier furnace cuts out
(3 replies)
lennox oil furnace
(3 replies)
furnace flame cuts out
(10 replies)
Oil burner Blower cycling on and off
(2 replies)
Oil Burner Furnace
(1 replies)

Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page
Search this Thread

Advanced Search

Bookmarks





Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 06:52 AM.