    Nordyne LED blinkin codes
    Can someone give me the codes for all the Nordyne LED blinks?

    My furnace was blining 4 times, I replaced the igniter and now it is blinking 2 times...

    All the codes would be greatly appreciated - thanks, in advance. :cool:
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Dec 8, 2007, 05:45 PM
    2 blinks. Pressure switch is open with inducer fan on.

    4 blinks Ignition failure (check ground)
    g_lundy's Avatar
    g_lundy Posts: 3, Reputation: 1
    New Member
     
    #3

    Dec 10, 2007, 06:52 AM
    Thanks for the info, but...

    ... are those the only 2? What if it blinks once, three or five times?
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #4

    Dec 10, 2007, 08:46 AM
    Power On = on
    Limit Circuit Open or External Load On "W" =1
    (Does not apply to Deck Switch, see below)
    Pressure Switch Open with Inducer On =2
    Pressure Switch Closed with Inducer On =3
    Ignition Failure (Check Ground)=4
    115 VAC & Neutral Reversed or no Ground =5
    False Flame or Gas Valve Relay Shorted =continuous


    Low Flame Sensor Signal = Continuous Flash
    Flame Present = ON
    RUBEN-69's Avatar
    RUBEN-69 Posts: 1, Reputation: 0
    New Member
     
    #5

    Jun 21, 2008, 10:47 AM
    My Uint Blink 5 Times
    nordyne1's Avatar
    nordyne1 Posts: 2, Reputation: 1
    New Member
     
    #6

    Jan 3, 2012, 06:11 PM
    Have westinghouse gas furnace residentiual Nordyne model FG6RA 072C-12A Solid red light when burner ingnights yellow light blinks eight times the burner fuel supply shuts off and blower continues

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Nordyne heater shuts off randomly [ 1 Answers ]

I've had someone look at my furnace, there stumped. It's a nordyne furnace, only a few years old, works great except at random times it just shuts off, usually in the middle of the night. It comes back on by just turning the thermostat off and then back on or opening the door on the front of the...

Nordyne furnace trouble [ 2 Answers ]

I have a Nordyne furnace, and the furnace got stuck in it's cycle. The vent blower would come on and that's it, so I had the circuit board replaced. Now, the a/c works but the furnace cycle won't even start. The light on the board just blinks twice. Any help would be great. Thanks.

Nordyne e2 electric furnace with ac [ 1 Answers ]

Hello I have an nordyne e23h012hn electric furnace, the control board is burnt and evaporator fan will not come on, replaced board and it burnt up to. The circuit on the board that burnt is the common line voltage to the fan, could it be the fan motor shorted causing this problem . Thanks chris ...

Nordyne air&heat [ 2 Answers ]

Wireing diagram for thermostat&heat strips 1-5kw 1-10kw

Nordyne heater fan not working right [ 1 Answers ]

I just moved into a 1991 mobile home with a heater of the same age. The furnace is a Nordyne Intertherm model MGHA 056ABFC-01 Forced air and natural gas heater. The problem is with the fan I turn the thermostat up to turn the furnace on. Once the burner heats up the fan turns on, The fan...


View more questions Search