Can someone give me the codes for all the Nordyne LED blinks?
My furnace was blining 4 times, I replaced the igniter and now it is blinking 2 times...
All the codes would be greatly appreciated - thanks, in advance. :cool:
Can someone give me the codes for all the Nordyne LED blinks?
My furnace was blining 4 times, I replaced the igniter and now it is blinking 2 times...
All the codes would be greatly appreciated - thanks, in advance. :cool:
2 blinks. Pressure switch is open with inducer fan on.
4 blinks Ignition failure (check ground)
Thanks for the info, but...
... are those the only 2? What if it blinks once, three or five times?
Power On = on
Limit Circuit Open or External Load On "W" =1
(Does not apply to Deck Switch, see below)
Pressure Switch Open with Inducer On =2
Pressure Switch Closed with Inducer On =3
Ignition Failure (Check Ground)=4
115 VAC & Neutral Reversed or no Ground =5
False Flame or Gas Valve Relay Shorted =continuous
Low Flame Sensor Signal = Continuous Flash
Flame Present = ON
My Uint Blink 5 Times
Have westinghouse gas furnace residentiual Nordyne model FG6RA 072C-12A Solid red light when burner ingnights yellow light blinks eight times the burner fuel supply shuts off and blower continues