Old Oct 26, 2007, 04:14 PM
onefleshforlife
New Member
onefleshforlife is offline
 
Join Date: Oct 2007
Posts: 5
onefleshforlife See this member's comment history on his/her Profile page.
No Ignitor Glow

Not sure the brand.. When I have the thermostat call for heat the vent blower and the blower both come on and there is no glow.. I have tested and bypassed the limit switches and that doesn't fix the problem. Now the diagnoses light flashes 4 times which is supposed to mean that there is an open limit switch ( so much for the diagnosis light ) .. I did unplug one wire at a time going to each limit switch according to the wiring and tested each connection for voltage and I traced the voltage all the way to the high limit switch and lost voltage when I connected the output wire to the high limit switch. With the input wire is connected and the output wire disconnected I have 24 volts once I connect the output wire I lost voltage. Does that mean the board is bad ??

Reply With Quote
 
     

Answers
 
 
Old Oct 26, 2007, 05:11 PM   #2  
Ultra Member
T-Top is offline
 
Join Date: Nov 2006
Posts: 1,159
T-Top See this member's comment history on his/her Profile page.
Are you checking voltage from common to each side of the limit switches?
  Reply With Quote
 
     
 
 
Old Oct 26, 2007, 06:54 PM   #3  
New Member
onefleshforlife is offline
 
Join Date: Oct 2007
Posts: 5
onefleshforlife See this member's comment history on his/her Profile page.
Yes I am...
  Reply With Quote
 
     
 
 
Old Oct 26, 2007, 07:20 PM   #4  
Junior Member
eschuen is offline
 
Join Date: Oct 2007
Posts: 62
eschuen See this member's comment history on his/her Profile page.
put a jumper across the high limit and see if the ignitor works
  Reply With Quote
 
     
 
 
Old Oct 26, 2007, 07:24 PM   #5  
New Member
onefleshforlife is offline
 
Join Date: Oct 2007
Posts: 5
onefleshforlife See this member's comment history on his/her Profile page.
Thanks I tried that didn't work also tried jumping all switches all to no avail..
  Reply With Quote
 
     
 
 
Old Oct 26, 2007, 07:49 PM   #6  
Ultra Member
T-Top is offline
 
Join Date: Nov 2006
Posts: 1,159
T-Top See this member's comment history on his/her Profile page.
Did you check to see if you have a 115v going to the glow coil after the inducer motor starts. Just making sure you dont have a hot surface ignitor burnt out and the furnace is out on flame failure. one more question, is the pressure switch closing after the inducer motor starts?
  Reply With Quote
 
     
 
 
Old Oct 27, 2007, 09:32 AM   #7  
New Member
onefleshforlife is offline
 
Join Date: Oct 2007
Posts: 5
onefleshforlife See this member's comment history on his/her Profile page.
Thanks .. I have no voltage at the ignitor and the inducer is working fine and I also bypassed it with a jumper still nothing..
  Reply With Quote
 
     
 
 
Old Oct 27, 2007, 05:04 PM   #8  
Ultra Member
T-Top is offline
 
Join Date: Nov 2006
Posts: 1,159
T-Top See this member's comment history on his/her Profile page.
Did the pressure switch close after the inducer motor started. At idle the pressure switch is open the inducer motor closes the pressure switch.
  Reply With Quote
 
     
 
 
Old Oct 28, 2007, 10:42 AM   #9  
New Member
onefleshforlife is offline
 
Join Date: Oct 2007
Posts: 5
onefleshforlife See this member's comment history on his/her Profile page.
Yes it works fine However there is no voltage supplied to the inducer... If I jumped the inducer shouldn't it be the same as the inducer motor closing the switch..
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
location of goodman ignitor