Home > Home & Garden > Heating & Air Conditioning   »   New AC installation - should both liquid and suction line dryers be installed?

 
Question Tools Search this Question Display Modes
Question
 
 
#1  
Old Jun 19, 2007, 07:14 PM
robflick23
New Member
robflick23 is offline
 
Join Date: Jun 2007
Posts: 2
robflick23 See this member's comment history on his/her Profile page.
New AC installation - should both liquid and suction line dryers be installed?

To make a long story short i've have a bad experience trying to get some repairs done to an existing aire-flow unit. $800 later i'm scrapping the unit. I've ordered (online) a new Rheem Classic 3 ton 13 seer condenser, coil and 100,000 btu gas furnace. I am not going to try to install the unit myself, i just want to gain some knowledge before i get someone to install it. I plan on requesting that they install a thermostatic expansion valve, a liquid line dryer, a liquid line sight, and a suction line dryer. Is that overkill? Any input would be appreciated.

Rob

Reply With Quote
 
     

Answers
 
 
Old Jun 19, 2007, 08:58 PM   #2  
hvacservicetech_07
Senior Member
hvacservicetech_07 is offline
 
hvacservicetech_07's Avatar
 
Join Date: Apr 2007
Location: Effingham, Illinois
Posts: 776
hvacservicetech_07 See this member's comment history on his/her Profile page.
Send a message via MSN to hvacservicetech_07
Well the TXV is a great idea, What are you replacing? The lineset, evap. coil, and condenser? If so I'd think the liquid line dryer should be enough. It won't hurt anything to install both....How much space are you heating/cooling? I think the 100,000 btu furnace may be a bit much.

Comments on this post
robflick23 disagrees: I've seen other answers from this memeber and respect his opinion, and he straight out answered my question.
J_9 agrees: I think that was supposed to be an agree!! ;-)
  Reply With Quote
 
     
 
 
Old Jun 20, 2007, 01:16 PM   #3  
robflick23
New Member
robflick23 is offline
 
Join Date: Jun 2007
Posts: 2
robflick23 See this member's comment history on his/her Profile page.
Um, looks like i screwed something up trying to rate your answer and i can't seem to edit it. Don't know why it says i disagree.

But yes, i'm replacing everything including line set. The furnace is rated at up to 100,000 btu but it only blows 1200 cfm and is matched to the coil. I'm not really sure where the 100,000 comes from.
  Reply With Quote
 
     
 
 
Old Jun 21, 2007, 03:12 AM   #4  
Vista
New Member
Vista is offline
 
Join Date: Jun 2007
Posts: 6
Vista See this member's comment history on his/her Profile page.
Quote:
Originally Posted by robflick23
To make a long story short i've have a bad experience trying to get some repairs done to an existing aire-flow unit. $800 later i'm scrapping the unit. I've ordered (online) a new Rheem Classic 3 ton 13 seer condenser, coil and 100,000 btu gas furnace. I am not going to try to install the unit myself, i just want to gain some knowledge before i get someone to install it. I plan on requesting that they install a thermostatic expansion valve, a liquid line dryer, a liquid line sight, and a suction line dryer. Is that overkill? Any input would be appreciated.

Rob
Dryers are normally placed on the high side (liquid) and should be good for the life of the AC unit. If the unit is ever exposed to the atmoshere then it would need to be replace. Use only one dryer. If the unit is new making a mod probably would void the warranty. There are to many controls involved here.

A thermostat with a remote bulb would be a little on the long side
  Reply With Quote
 
     
 
 
Old Jun 21, 2007, 04:11 PM   #5  
hvacservicetech_07
Senior Member
hvacservicetech_07 is offline
 
hvacservicetech_07's Avatar
 
Join Date: Apr 2007
Location: Effingham, Illinois
Posts: 776
hvacservicetech_07 See this member's comment history on his/her Profile page.
Send a message via MSN to hvacservicetech_07
I would actually like to add something to my last comment, don't add a suction line dryer if you are installing a system with a scroll compressor.
  Reply With Quote
 
     
 
 
Old Jun 21, 2007, 04:53 PM   #6  
NorthernHeat
Heating & Air Conditioning Expert
NorthernHeat is offline
 
Join Date: Oct 2006
Location: IN
Posts: 1,355
NorthernHeat See this member's comment history on his/her Profile page.NorthernHeat See this member's comment history on his/her Profile page.
You didn't say if it was R-22 or 134A. Just a liquid drier. Lineset is not necessary if it is r-22 for r-22 unless you expect a leak in the lineset. All 13 seer units will come withe a TXV from the factory, starting with 12 seer and up, in the Rheem/Ruud line.
  Reply With Quote
 
     
 
 
Old Jun 21, 2007, 06:41 PM   #7  
T-Top
Senior Member
T-Top is offline
 
Join Date: Nov 2006
Posts: 843
T-Top See this member's comment history on his/her Profile page.
If you had a burn out on the old system I would put one in the liquid and suction line. After six months remove the one from the suction line and replace the one in the liquid line. To over protect your system will not hurt it. We all know that the new A/C systems are not cheap.
  Reply With Quote
 
     


Question Tools Search this Question
Search this Question:

Advanced Search
Display Modes

 
Similar Sponsors

Similar Questions
Question Asker Topic Answers Last Post
suction part of line sets davidc Heating & Air Conditioning 7 May 26, 2007 05:32 AM
fridgidaire dryers Amy Horn Appliances 1 Mar 7, 2007 01:03 PM
Washer and Dryers Kenbarb Appliances 0 Feb 22, 2007 06:05 AM
check for suction line leaks donmacc Lawn & Garden 1 May 15, 2006 09:36 AM
New sewer and water line installation lreeder Plumbing 4 Apr 13, 2006 05:31 AM




Copyright ©2003 - 2007, Ask Me Help Desk.
All times are GMT -8. The time now is 01:03 AM.

Content Relevant URLs by vBSEO 3.0.0 RC6 © 2006, Crawlability, Inc.