    Mercury thermostat vs digital thermostat
    Last year I replaced the old Honeywell thermostat in my home with a programmable one. I figured that the set back feature would save me some money during the heating season. I don't think it did. Then this summer I kept using this thermostat for the cooling season, but I kept it at a constant temperature. My heat pump seemed to run for only a short time, but it ran often. The temperature in the house never changed from the setpoint, which is what I assume a digital thermostat is supposed to do, but I became a bit concerned about the constant cycling of the heat pump and I decided to switch back to the old thermostat (mercury type) a few weeks ago. Within a few hours the humidity in the house dropped 12-15 % to about 40. This never happened with the programmable thermostat. Now back in the winter, when I set the thermostat back, it seemed that when it returned to the "normal" setting it always ran for a few minutes, then it called for the auxiliary heat.
    So it is my opinion that setting back a thermostat on a heat pump is really not a viable option because the resistance heat required to raise the temperature cancels the savings attained during setback hours. And that precise control during the cooling season doesn't allow enough run time to properly reduce the humidity in the residence.
    Anyone else share these views?
    wmproop's Avatar
    wmproop Posts: 3,749, Reputation: 91
    Ultra Member
     
    #2

    Jul 21, 2008, 08:27 PM
    No
    KISS's Avatar
    KISS Posts: 12,510, Reputation: 839
    Uber Member
     
    #3

    Jul 21, 2008, 08:52 PM
    Quote Originally Posted by Missouri Bound
    So it is my opinion that setting back a thermostat on a heat pump is really not a viable option because the resistance heat requred to raise the temperature cancels the savings attained during setback hours. And that precise control during the cooling season doesn't allow enough run time to properly reduce the humidity in the residence.
    Anyone else share these views?
    You have some interesting points:

    If you want/need dehumidification, you need to purchase a stat which will try to dehumidify. It does this at the expense of exact temperature control. Lowering humidity is best accomplished by lowering fan speed. Hvac1000, I believe has posted a schematic where a humidistat controls the fan speed. High/low. It makes sense.

    Em heat usually can be turned off and/or tied to outside temperature. The temperature set in the stat and a corresponding outdoor sensor will lockout the compressor below a certain temperature. The actual algorithm seems to be guraded among manufacturers as to when emg heat kicks in. Two ways seem plausable:
    1) compressor is locked out
    2) It took to long to raise the temperature
    3) Difference between Setpoint and Measured Value is Large.

    The adpative control algorithms in some tstats try to make the SP = to some value by the time you set, rather than change the temp at that time.
    Those should not invoke emergency heat.

    It is true that a very steep abrupt setback. Just changing the temperature as part of a setpoint schedule might make the energy meter spin.

    One or two of the Honeywell Vision Pro stats have a dehumidification option.

Not your question? Ask your question View similar questions

 

Add your answer here.


Check out some similar questions!

Replacing a mercury thermostat for a Hunter Model 44110 [ 3 Answers ]

I have just purchased a Hunter Programmable Thermostat Model 44110. I have taken out the front panel off my old thermostat and notices that my wires are red, white, yellow and green. The panel for the Hunter 44110 has the connections for G, Y, W and the RC and RH have a jumper. What do I do with...

Replacing Analog Thermostat with Non-Programmable Digital Thermostat [ 1 Answers ]

Replacing Analog thermostat with White, Yellow, Red, & Black wiring with non-programmable digital thermostat Model #RTH3100C. Please help!!

Replace T87F thermostat with digital thermostat [ 1 Answers ]

My T87F has two wires Red and White. No code indicating how to connect to the new digital on.

How to Replace Old Carrier Thermostat (mercury filled) [ 2 Answers ]

I am wanting to replace my old theromstat with a programmable theromstat. However, I have run into a slight issue. The old thermostat only has two wires coming out of the wall and three wires ( yellow, red, white) tied to the mercury. The one white wire is going back into a radial button that...

Converting mercury bulb thermostat to digital [ 3 Answers ]

I have a TRANE XL1200 Weathertron heat pump with auxiliary heat. It is controlled by a Trane 3AAT80A1A1 mercury bulb analog thermostat. I have purchased a RiteTemp 8050C digital programmable thermostat to replace it. The analog thermostat has wired terminals marked O,R,T,G,Y,X2,B,W and F. It...


View more questions Search