    pag1012's Avatar
    pag1012 Posts: 2, Reputation: 1
    New Member
     
    #1

    Sep 16, 2011, 01:45 PM
    Magic Chef furnace
    Hello, I have an older 80s model Magic Chef furnace - G83-75D-5. The furnace worked fine all last winter. I put in a new air filter in prep of winterizing and now the unit will not come on. The paperwork says to be sure the door is replaced correctly due to the safety interlock switch... I have taken the door off and put it back on serveral times with no luck. Any suggestions?

    Thanks so much.
    Pam
    T-Top's Avatar
    T-Top Posts: 1,871, Reputation: 100
    Ultra Member
     
    #2

    Sep 16, 2011, 04:57 PM
    The door switch is made to kill power to the furnace if the door is removed. That way no one can get hurt if the system kicks on with your hands in it or get into the electric accidentally. Switches do go bad. If you know the door is in right you can try bypassing the switch to see if it will work. You have to turn power to the system off first and the join the two wires together and see if it works after restoring power. To bypass a safety switch permanently is never a good idea.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Magic chef furnace wiring schematic [ 27 Answers ]

I have an old Magic Chef gas furnace in my garage. Gas is connected, but wiring for fan and thermostat are a question. 55K BTU, 12 amp blower. Need to know what wires to connect to thermostat. Also, there are three wires exiting furnace. I know which ones power the 110v blower, but there is a...

Older magic chef furnace [ 1 Answers ]

I have a older magic chef furnace and my father in law messed with the wiring now the pilot is lit but furnace won't ignite there are two wires from the gas valve both are black where do they go to

Magic chef furnace models [ 0 Answers ]

I have a Magic Chef LP gas furnace (Model EG6E100DC-1). Last week the heat wasn't kicking on in the morning and found that the draft inducer blower had cooked a bearing. I shut down power to the unit, removed the blower, sourced a new blower, installed exactly as I had removed it. The draft inducer...

Magic Chef Ulta 97 Furnace [ 1 Answers ]

I have an Ultra 97 gas fired heater made by Magic Chef. I assume its about 15-18 years old. When the heater kicks on, the only thing that happens is that the blower starts running but the ignitor does not ignite. There are 2 flat cylinder type switches when you open up the door. If you tap on...


View more questions Search