    Lennox G12 - Replacing Gas Valve
    10/25/09

    I have an old Lennox G12RQ3-82 furnace with a Robertshaw 7000 gas valve. Can I
    Switch out this standing pilot unit with an intermittent pilot model, say a White Rogers
    36E gas valve? I want to upgrade the system so that I'm not burning a pilot light
    24-7 all winter.

    Any thoughts would be helpful.

    George
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Oct 25, 2009, 01:15 PM
    A spark ignition pilot system will work. You will need the gas valve/ignitor box/and spark ignitor pilot lite assembly. These usually come in a complete kit form with all the parts you need in one box. Both Honeywell and White Rodgers as well as RobertShaw offer complete kits I believe.

    Whatever you do forget about putting together your own kit from various parts. While I am not saying a experienced HVAC mechanic cannot do that it just takes great skill and many parts books to figure what will be compatible with what and what will be UL/CSA approved.

    It takes some skill to install the kits successfully and some special tools are needed to do the job correctly. In many cases it might be more adventages to contact a local HVAC service person to do the job.

    A special note on propane gas.
    If you are using propane and you are attempting to do this yourself be extremely careful. While Natural and Propane are both gases Propane is more sensitive to incorrect adjustments and many manufactures do not offer conversion kits for this reason for propane. Do not attempt to put a kit together for propane, only use a manufactures complete kit listed for propane use.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Replacing a Saddle Valve [ 3 Answers ]

I Have a saddle valve that allows water flow to a furnace humidifier. I can not shut it off nor turn the valve stem. Can a saddle valve be replaced or does one install a new piece of copper pipe and then install the valve?

Replacing shower valve [ 6 Answers ]

Remodeling our bathroom and need to switch out the shower valve. The walls are open, so everything is accessible. If it's harder than this, or I'm missing something, please let me know... All outside the wall... 1 - disassemble the guts of the valve so as to not damage it with heat 2 -...

Replacing Lennox 18K201 control unit with 31M73 [ 3 Answers ]

I am replacing my old burnt 18k201 circuit board with the new 31m73 on my Lennox air handler and have run into a problem with the wiring. The exiting wiring harness is a 14 pin P2 connector and the new one has a 10 pin J85. Is there an adapter available to mate the 2 or at least some intructions on...

Replacing Shut off valve on PVC [ 6 Answers ]

My water line going to the dishwasher was leaking so I replaced it. Now I've figured out that the shut off valve is leaking at the nut that goes over top of the PVC pipe. I bought a replacement valve but can't figure out how to get the old one off the PVC pipe. I'm assuming it has glue/cement...

Replacing Gas Oven Valve [ 2 Answers ]

I recently had an employee from the local gas company in my kitchen and he looked at the shut off valve for my gas oven. He suggested I call a plumber and change the valve because it was very old and prone to failing. What are the best types of gas shut off valves that I should ask a plumber to...


View more questions Search