    Sorry for the double post but I couldn't find a way to edit the first one or delete it.

    Woke up nice and warm last night, upstairs ac had stopped working. Compressor outside is running, but no blower. Tried manually setting the fan from Auto to ON, nothing. Doesn't matter if I have it set to heat or AC. Using a Honeywell programmable thermostat, swapped the upstairs one with the downstairs one, no difference. (Checked the fuses at the main fuse box, all good.) I have a Lennox Value Series model 80UHG3-75A-3. I checked the voltage at what I believe is the transformer, its on the right in the attached picture, it read at 25v, also according the diag lights the circuit board reports everything is normal. So I assume the issue is the blower fan? I was able to spin it with no resistance. Anything else I can do to troubleshoot this?

    Thanks,
    Attached Images
     
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Jun 8, 2009, 04:51 PM
    You can test the motor by applying the correct voltage directly to the motor if you have the skill to do that. Naturally you have to disconnect the power wires feeding the motor to prevent feed back. It could also be the blower motor relay causing this problem. Since the motor is not trying to start the capacitor for the motor is probably not at fault.
    harrisburgTony's Avatar
    harrisburgTony Posts: 5, Reputation: 1
    New Member
     
    #3

    Jun 8, 2009, 05:53 PM
    Quote Originally Posted by hvac1000 View Post
    You can test the motor by applying the correct voltage directly to the motor if you have the skill to do that. Naturally you have to disconnect the power wires feeding the motor to prevent feed back. It could also be the blower motor relay causing this problem. Since the motor is not trying to start the capacitor for the motor is probably not at fault.
    Thanks, as an update I removed the control panel to find a large burn mark on the back, odd, since the diag lights are blinking a normal status, but I am guessing this is a bad thing and the board will need to be replaced.
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #4

    Jun 8, 2009, 06:52 PM
    It is possible that burn mark does mean the circuit board is shot. That is usually the case. Post a PIC if you can.
    mygirlsdad77's Avatar
    mygirlsdad77 Posts: 5,713, Reputation: 339
    Plumbing Expert
     
    #5

    Jun 8, 2009, 07:06 PM

    Burn marks on back side of control board almost always indicate fried board. Im betting a new board will solve the problem.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Kirkland Signature, by whirlpool; Dryer stopped heating and timer stopped working [ 2 Answers ]

I have a Kirkland Signature, by whirlpool Dryer that stopped heating and timer stopped working at the same time. What may have caused this?

Lennox blower don't come on at all it clicks [ 1 Answers ]

2 green lights flash on the furnace, but the blower want come on. It clicks like its going to come on but don't

Lennox furnace no blower [ 1 Answers ]

Have lennox G20 Q4 furnace. Burners work when called for but no blower. Blower will not run when selected at thermostat. Had a new circuit board for the G20 Q3 furnace, installed it. Result was blower ran prior to burners igniting and blower would not go off after burner shut down. Changed...

Lennox furnace, blower not working [ 1 Answers ]

I have a 1000sqft town home with a Lennox furnace about 18 years old. My furnace blower is not working. I currently uneployed and job seeking and would like to avoid the cost of replacing the entire furnace. What sort of cost should I expect to replace the blower?

Previously working electrical outlets stopped working [ 2 Answers ]

Hi Everyone A wall of electrical outlets in my kitchen just stopped working. They were working just fine about a month ago. I tried checking the circuit box, and turning the circuits on/off just to make sure anything that has been tripped was turned on back again. But it didn't work for the...


View more questions Search