Ask Experts Questions for FREE Help !
Ask
    Daniel F's Avatar
    Daniel F Posts: 3, Reputation: 1
    New Member
     
    #1

    Nov 30, 2008, 09:14 PM
    Janitrol Furnace
    Hello -

    I have a Janitrol Model # GUE060-E Furnace. The blower will not shut off unless I power it off by removing the bottom panel. I hear a clicking sound like it wants to shut off. The thermostat is set to auto mode. Could it be the relay?


    Thanks,

    Dan
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Nov 30, 2008, 11:12 PM
    It could be a fan and limit control if it is a gas furnace or relay depending upon which device controls the blower motor.
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #3

    Nov 30, 2008, 11:13 PM
    2Xpost
    Daniel F's Avatar
    Daniel F Posts: 3, Reputation: 1
    New Member
     
    #4

    Dec 1, 2008, 08:27 AM
    HVAC -

    Thank You for your response. I failed to mention that the furnace is not powered by gas.
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #5

    Dec 1, 2008, 08:38 AM
    On electric units either a sequencer is bad causing the blower to stay on or a fan blower relay.
    Daniel F's Avatar
    Daniel F Posts: 3, Reputation: 1
    New Member
     
    #6

    Dec 1, 2008, 09:01 AM

    HVAC -

    Thank You very much. I'll give those a try. What a blessing you have been to me.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Janitrol furnace blower doesn't come on [ 1 Answers ]

It's a Janitrol Conditioner Gas-Fired (FES90-05 type S, a 115 volt transformer 50-60 cycvle and a Honeywell Comfort thermostat. Pilot works fine, but thermostat set higher is not making burners light and blower come on. What might be the problem? Thanks!:)

Janitrol furnace [ 4 Answers ]

I have to down to the basement and manuel turn the blower on it will not go on on auto only manuel what do you think is wrong thanks tboy56

My janitrol furnace is not responding [ 2 Answers ]

Furnace - Janitrol GMP100-3 (circa 2000) I can turn on the air conditioner and the fan, but the furnace isn't working at all. There are no pilots lit. It's like it has no power, but when I remove the panel and check the wires, I can get the red LED light to come that indicates whether the...

Janitrol furnace won't ignite [ 1 Answers ]

I just replaced the flame sensor on my janitrol gmp050-3 and it still won't fire up to produce heat. It does everything but ignite please help it is cold and miserablein the house. Don't know what elese to do.:confused:


View more questions Search