Ask Experts Questions for FREE Help !
Ask
    Dave from OBX's Avatar
    Dave from OBX Posts: 2, Reputation: 1
    New Member
     
    #1

    Nov 7, 2013, 05:56 PM
    How to wire a Honeywell RTHL3550 from a Janitrol HPT 18-60
    I need the correct wiring from a Janitrol HPT 18-60 to a Honeywell RTHL3550. I have a heat pump with an emergency heat strip.

    The Janitrol wiring is as follows:
    Y=YELLOW
    G=GREEN
    R=RED
    O=ORANGE
    W2=WHITE
    E=SILVER (GRAY)
    C=BLUE
    Need to know corresponding terminals on the Honeywell
    they are as follows:
    L=
    AUX/E=
    G=
    O/B=
    Y=
    R=
    Rc=
    Thanks,
    Dave from OBX
    Grady White's Avatar
    Grady White Posts: 1,417, Reputation: 59
    Ultra Member
     
    #2

    Nov 7, 2013, 08:46 PM
    R=Red
    Y=Yellow
    G=Green
    O/B=Orange
    Aux/E=White & Silver

    I'm surprised there is no "C" (common) terminal on the new stat.

    I searched Honeywell's site for an RTHL 3550 without success. Are you sure the model # is correct?
    Dave from OBX's Avatar
    Dave from OBX Posts: 2, Reputation: 1
    New Member
     
    #3

    Nov 8, 2013, 07:40 AM
    Quote Originally Posted by Grady White View Post
    R=Red
    Y=Yellow
    G=Green
    O/B=Orange
    Aux/E=White & Silver

    I'm surprised there is no "C" (common) terminal on the new stat.

    I searched Honeywell's site for an RTHL 3550 without success. Are you sure the model # is correct?
    There is no C on the Honeywell. If you Google Honeywell RTHL3550 with no space it will come up. Thanks

Not your question? Ask your question View similar questions

 

Add your answer here.


Check out some similar questions!

Replacing a Trane thermostat with Honeywell RTHL3550? [ 1 Answers ]

The wiring is completely different so we called Habib from India and got the wiring straight but it won't kick on when it needs to and the aux tries to kick in and it won't work either, what do we do to get it working... I'm cold & need help asap

Replacing Janitrol HPT 18-60 with Honeywell RTH2310 [ 1 Answers ]

Replacing Janitrol HPT 18-60 with Honeywell RTH2310 The wires coming from my Janitrol are: Y-Yellow, G-Green, R-Red, O-Orange, W2-White, E-Black, C-Blue The New Honeywell slots are labeled: Rh, Rc, W, Y, G... Which of the current Janitrol wires goes in which slot?

How to wire from Janitrol HPT 18-60 to a Hunter 44360 [ 2 Answers ]

Help! My Son bought me a Hunter 44360 for Christmas. I have a Janitrol now I sure could use some help with the wirring. The Present Janitrol is wirred: Y to Yellow wire G to green Wire R to Red Wire O to Orange Wire W2 and E are jumpered to the Wite Wire C to Blue Wire The New Hunter has...

Janitrol 7 wire to Honeywell RTH230B 5 wire [ 3 Answers ]

I currently have a Janitrol digital thermostat. I can't read the model #. It has 8 terminals and 7 wires hooked up. Terminal - Color Y - Yellow Com - Blue R - Red G - Green w2 - Looks white E/w3 - Looks pink O - Orange B - Nothing

Janitrol hpt 1860 to honeywell rth230b [ 2 Answers ]

Again, I checked the make and models of my thermostats to ensure I don't goof nothing Up. My janitrol hp 1860 wires: yellow to y, green to g, red to r. blue to o, White to e and jumpered to w2 and brown to c. The Honeywell RTH230B has Only 5 contacts, Rh, Rc, W,Y and G. I guess just for...


View more questions Search