    How to replace a carrier thermostat with a honeywell
    My Carrier programmable thermostat has no display indication. I openned it and tightenned all wires. I also turned the power off and on to see if that would help. It didn't. I had this similar problem a two month ago but the display came back on its own. Please help. It's hot in SC.
    wmproop's Avatar
    wmproop Posts: 3,749, Reputation: 91
    Ultra Member
     
    #2

    Jun 26, 2010, 07:19 AM
    1st buy the right tstat for your system
    2nd ,be sure to mark/tag each wire as you remove so you will remember what color wire goes to which post
    3rd re-install each wire to to correct post in your honeywell tstat
    Follow instructions with the new tstat as to the setup and programing
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #3

    Jun 26, 2010, 07:24 AM
    Quote Originally Posted by kully0 View Post
    My Carrier programmable thermostat has no display indication. I openned it and tightenned all wires. I also turned the power off and on to see if that would help. It didn't. I had this similar problem a two month ago but the display came back on its own. Please help. It's hot in SC.
    If the thermostat is preventing the unit from running/blank screen then the first thing you need to do is make sure the main power is turned on to the system components both inside and outside. Then once you have proven the system has power you need to check to be sure the 24 volt low voltage control power is available. It could be a bad thermostat as you figure it to be OR it could be a lack of 24 volt control circuit voltage causing the thermostat and other controls not to work.

    Before you start replacing parts like the thermostat you need to make sure that the control voltage as well as the operating power is available, Then if all the power sources are present it is a good possibility the thermostat is defective.

    Usually a quick test is to jump the R (RED) wire to the G (GREEN) wire that goes to the thermostat. If both power sources are available the fan motor on the furnace or indoor air handler should run. NOTE: the above info is for standard HVAC system control wiring and color code.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Replacement of Carrier Heat Pump Thermostat with Honeywell TH6000 series thermostat. [ 4 Answers ]

I have a Carrier Series 50QT Electric heat pump that still uses the original non programmable thermostat. I am trying to replace it with Honeywell TH6000 series programmable thermostat. The wiring on the existing Thermostat as follows: O - White, I am thinking this is the Reversing Valve? Y...

Carrier thermostat to honeywell [ 0 Answers ]

Replacing old carrier model to honeywell rth3100c Having trouble only blows cool air on heat mode

Replace Brant standard thermostat with HOneywell thermostat [ 40 Answers ]

HI guys, I have a Bryant Heat Pump system with axilaury heat and A/c, I want to replace the Honey programmable thermostat, but still reluctant to install it myself since the wire label different. My new Honeywell model is TH6110D1005 and it has following wire label. G O/B (W) C Y R Rc ...

Thermostat change from carrier to honeywell [ 3 Answers ]