    How to replace boiler{ Honeywell} zone valve
    Honeywell 40004850-001 isn't working. The lever to manually open valve freely moves back and forth. What do I need to do to replace this valve?
    siberianair's Avatar
    siberianair Posts: 360, Reputation: -4
    Full Member
     
    #2

    Aug 5, 2009, 09:25 AM

    Are you trying to replace the power head of the whole valve?
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #3

    Aug 5, 2009, 02:38 PM
    http://customer.honeywell.com/Techli...0s/60-2133.pdf
    mygirlsdad77's Avatar
    mygirlsdad77 Posts: 5,713, Reputation: 339
    Plumbing Expert
     
    #4

    Aug 5, 2009, 03:51 PM

    Do you have shut off valves on both sides of zone vavle? IF you do, shut them off, and remove the four screws at each corner of zone valve(dont do this if you don't have isolation valves at each side of zone valve). Then pull the head off the vavle. Now, there will be a rod sticking out of valve cover plate that has to flat sides. See if you can move this rod with your fingers. If you can, you just need to get a new head(the part you just took off). If you cant, you will need to cut out complete valve assembly and solder in a new one.

    If you don't have any isolation valves, you will need to shut of incoming water to boiler, drain complete system, then replace either the head of complete unit(unless you have a newer style zone valve that only the head needs to be replaced on) Once your done replacing head or complete valve, turn water back on to boiler, then go and bleed all of the air out at bleeders on registers. If you have to break into the system, and there are no isolation valves, this can be a very time consuming project to take on. You May want to think about having a pro in to do the work. Good luck and please let me know how you make out. Lee
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #5

    Aug 5, 2009, 05:11 PM
    If you have the older style valve then you can use this kit with the old valve body to convert to newer style unit. This way you do not have to remove (unsolder) the old valve body. Save time and a headache.

    Conversion Kits:
    Conversion kits for converting old style (series 1-5) valve
    bodies to accept 40003916 Powerhead (use with V4043,
    V4044, V8043, V8044). Includes metal plate with driveshaft
    and rubber ball, O-Ring and four screws.
    Two-way water valve body: 40003918-006.
    Three-way water valve body: 40003918-007.
    Two-way steam valve body: 40003918-008.
    QuickMick's Avatar
    QuickMick Posts: 7, Reputation: 1
    New Member
     
    #6

    Sep 21, 2012, 10:15 AM
    I just need to replace the diaphragm. It was replaced last Dec. 2011, It is not working again this year. It may be stuck. I would like to open it and see if I can free it with WD-40 or replace it if it is damaged already.

    Mick
    [email protected]
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #7

    Sep 21, 2012, 11:01 AM
    It is a swing ball style?

    See below

    https://customer.honeywell.com/resou...0s/60-2133.pdf

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search


Check out some similar questions!

Honeywell zone valve seems stuck open [ 19 Answers ]

I manually opened one of my home's five Honeywell zone valves (V8043E-1012) by mistake. I meant to open a different valve. The one I opened had its thermostat set to its lowest temp setting, as it controls heat to a space I hardly ever heat. The next day the valve was still in the open position...

Are zone valves or zone thermostats possible with a steam boiler? [ 1 Answers ]

I have an old 4 story building with one thermostat controlling the steam heat to all floors. There is a commercial space on the ground floor and they are complaining that they don't get enough heat sometimes (and on occasion get too much!) They have suggested that there is some way to place a...

Changing Boiler from ONE zone into Two Zones [ 2 Answers ]

I'm considering buying a big renovated antique house in MA that has 14 rooms, 4,000 sq.ft Living area WITH ONE ZONE HEATING. All the windows have been upgraded and half of the rooms had insulation blown into the walls. The house has a burnham boiler, using natural gas with old fashioned steam...

Zone valve [ 1 Answers ]

Got a white rogers zone valve spinning and not stopping ,has my end switch burned out .


View more questions Search