    Honeywell T8001 Thermostat - Blank Display
    Kids while playing in the backyard were banging against the outside compressor unit and I found later that the display on the thermostat is now blank. So I can not switch on heating or air conditioning. Since my house has two units one for upstairs and one for downstairs, I tested by swapping the two thermostat units. The thermostat unit itself is OK as swapping makes the thermostat with blank screen to light up and the working thermostat does not work when put on the defective location.

    There appears to me some fuse issue either at the furnace in the attic or at the outdoor compressor, but unable to trace the fuse or the problem. Please help.
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Jul 9, 2007, 01:29 AM
    You are missing 24 volt power to the thermostat. You will probably need a meter to track down the problem. Actually there is no simple cure for this except to test the components (transformer and wiring) to find the problem. You can check to see if the circuit breaker needs to be reset for the inside unit and that is right in your electric panel. The outside unit will have a disconnect which might be fused. That can be checked also.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Programmable thermostat went blank [ 12 Answers ]

Our thermostat (which has been serving solely as a thermometer since the last time we used the heat in the spring) blanked out yesterday afternoon. I checked the inside temp. during the day, then last evening the face was completely blank. It is completely unresponsive to any button pushing. I...

Thermostat display is blank [ 6 Answers ]

I have a Honeywell programmable thermostat and the display is blank. We had a bad storm and the power went out. I have checked the breaker and reset it. The blower will come on when I switch it to ON, but nothing else works. Can someone help?

Blank Thermostat [ 6 Answers ]

Hi Guys, I had the A/C unit running fine today... then all of a sudden my thermostat went blank... It was raining on and off today here in Plano, Texas... It is a Carrier A/C furnace unit, controlled by a Honeywell Thermostat... This thermostat gets its power from the unit itself... In the...

Thermistat display goes blank and comes back intermittently. [ 2 Answers ]

I have a Bryant (Carrier) programmable thermidstat that has worked without problem for 2+ years. The problem is that the LCD and backlight goes out intermittently during the time the system is not running. I have yet to determine the exact sequence of when this happens but without intervention the...


View more questions Search