Honeywell Synchron 40004850-001

Asked Nov 24, 2010, 06:11 PM —
I have a 3 zone Lennox boiler system. One zone not working. I get hot water to two of the zones both supply and return. Non-working zone has hot water to the supply cold on the return. I first thought the circulator was out but it has current from the Aquastat, plus the other two zones have hot on both return and supply sides. When I touch the three Synchron, the two zones that have hot water are warm to the touch, non working is cold. I placed lever to manuel-no change.
Does this sound like the synchron is out, if so how do I replace?

Thanks



Check out some similar questions!

Synchron zone valve replacement parts [ 7 Answers ]

I have had two heat/air conditioning guys out to check my unit and they both said that my zone damper needs to be replaced. Apparently I have two for dual control. I have one with a part # that reads 645 24V 60HZ 6W 60 RPH 37944L-6 9218 The name synchron is on the part. It would be great if...

Probem with Honeywell Synchron motorized valve [ 4 Answers ]

I have a gas fired boiler that uses seven Honeywell Synchron valves for zoned heating. All the valves are model V8043E1012. One of the valves seems to be stuck in the on position regardless of the thermostat setting. Also, I noticed the slide switch (auto or manual) on the valve in question has...

Obnoxious 001 calls [ 5 Answers ]

Lately I've been getting calls from 001 407 7654321 when I answer it takes them a second to "pick up" and then a woman says hello. It doesn't matter what I say, they usually end up hanging up right after. They call 3-4 times a day, usually around the same time, starting around 11am. I tell...

Where to find the model number on my Honeywell Synchron zone valve [ 5 Answers ]

Where to find the model number on my Honeywell Synchron zone valve. I think the Powerhead and/or motor has gone bad. I had no heat in my master BR this morning and after verifying the Thermastat was kicking in I went down and tried to check the valves. This is just 1 zone out of 5 (3 other...

Concord 46555-001/b dead [ 1 Answers ]

My heater was working. Just stopped. When I turn up the thermistat you can hear it click. The motor does not turn on. I was trying to wool the ignitor, and it tried to work. Is it the ignitor?



View more Heating & Air Conditioning questions Search
 
Thread Tools Search this Thread
Search this Thread:

Advanced Search

Add your answer here.

Remove Text Formatting

Undo
Redo
 
Decrease Size
Increase Size
Bold
Italic
Underline
Align Left
Align Center
Align Right
Ordered List
Unordered List
Decrease Indent
Increase Indent
Insert Email Link
Wrap [QUOTE] tags around selected text
Wrap [CODE] tags around selected text
Wrap [HTML] tags around selected text
Wrap [PHP] tags around selected text
Wrap [YOUTUBE] tags around selected text
Notification Type: