Question
 
 
Old Dec 5, 2006, 02:39 AM
RickJ's Avatar
RickJ
Administrator
RickJ is offline
 
Join Date: Aug 2005
Location: Cave 4, Qumran
Posts: 6,889
RickJ See this member's comment history on his/her Profile page.RickJ See this member's comment history on his/her Profile page.RickJ See this member's comment history on his/her Profile page.RickJ See this member's comment history on his/her Profile page.RickJ See this member's comment history on his/her Profile page.RickJ See this member's comment history on his/her Profile page.
Heating & Cooling Maintenance, Repair & Troubleshooting Frequently Asked Questions

Check out these tips and explanations, below, from our Heating and Cooling Expert. Of course, you're also welcome to post questions to this board for more information: Just click the "Ask about Heating & Air Contidioning" button at the top of the page.

Reply With Quote
 
     

Answers
 
 
Old Jan 29, 2007, 07:13 AM   #21  
NorthernHeat
Heating & Air Conditioning Expert
NorthernHeat is offline
 
Join Date: Oct 2006
Location: IN
Posts: 1,355
NorthernHeat See this member's comment history on his/her Profile page.NorthernHeat See this member's comment history on his/her Profile page.
Flame sensor



If my answer helped, please click Rate this Answer! below. Thanks!

Comments on this post
jdea agrees: Excellent picture and help
Attached Images
 
  Reply With Quote
 
     
 
 
Old Jan 29, 2007, 07:33 AM   #22  
NorthernHeat
Heating & Air Conditioning Expert
NorthernHeat is offline
 
Join Date: Oct 2006
Location: IN
Posts: 1,355
NorthernHeat See this member's comment history on his/her Profile page.NorthernHeat See this member's comment history on his/her Profile page.
Thermocouple





If my answer helped, please click Rate this Answer! below. Thanks!
Attached Images
 
  Reply With Quote
 
     
 
 
Old Jan 29, 2007, 07:33 AM   #23  
NorthernHeat
Heating & Air Conditioning Expert
NorthernHeat is offline
 
Join Date: Oct 2006
Location: IN
Posts: 1,355
NorthernHeat See this member's comment history on his/her Profile page.NorthernHeat See this member's comment history on his/her Profile page.
Gas valve (Standing pilot model)




If my answer helped, please click Rate this Answer! below. Thanks!
Attached Images
 
  Reply With Quote
 
     
 
 
Old Jan 29, 2007, 07:37 AM   #24  
NorthernHeat
Heating & Air Conditioning Expert
NorthernHeat is offline
 
Join Date: Oct 2006
Location: IN
Posts: 1,355
NorthernHeat See this member's comment history on his/her Profile page.NorthernHeat See this member's comment history on his/her Profile page.
Capacitors




If my answer helped, please click Rate this Answer! below. Thanks!

Comments on this post
cburns : it sucks. it is not an aswer at all
Attached Images
  
  Reply With Quote
 
     
 
 
Old Jan 29, 2007, 07:37 AM   #25  
NorthernHeat
Heating & Air Conditioning Expert
NorthernHeat is offline
 
Join Date: Oct 2006
Location: IN
Posts: 1,355
NorthernHeat See this member's comment history on his/her Profile page.NorthernHeat See this member's comment history on his/her Profile page.
Purge and balance




If my answer helped, please click Rate this Answer! below. Thanks!
Attached Images
 
  Reply With Quote
 
     
 
 
Old Jan 29, 2007, 07:38 AM   #26  
NorthernHeat
Heating & Air Conditioning Expert
NorthernHeat is offline
 
Join Date: Oct 2006
Location: IN
Posts: 1,355
NorthernHeat See this member's comment history on his/her Profile page.NorthernHeat See this member's comment history on his/her Profile page.
Circuit boards




If my answer helped, please click Rate this Answer! below. Thanks!
Attached Images
  
  Reply With Quote
 
     
 
 
Old Jan 29, 2007, 08:07 AM   #27  
NorthernHeat
Heating & Air Conditioning Expert
NorthernHeat is offline
 
Join Date: Oct 2006
Location: IN
Posts: 1,355
NorthernHeat See this member's comment history on his/her Profile page.NorthernHeat See this member's comment history on his/her Profile page.
Blower turns on but there is no heat.

Thermostats only control a fan relay, fan center or circuit board to turn on the blower motor.

Although these relay's are necessary for cooling to work, they have nothing to do with the heating operation or outdoor cooling section of the equipment.

Electric furnaces may or may not use this relay controlled by the fan switch of the thermostat.



If my answer helped, please click Rate this Answer! below. Thanks!

Comments on this post
wirechaser1 : I did not know this. Thanks!
  Reply With Quote
 
     
 
 
Old Jan 29, 2007, 08:36 AM   #28  
NorthernHeat
Heating & Air Conditioning Expert
NorthernHeat is offline
 
Join Date: Oct 2006
Location: IN
Posts: 1,355
NorthernHeat See this member's comment history on his/her Profile page.NorthernHeat See this member's comment history on his/her Profile page.
What is a flame sensor?

The flame sensor, seen here is typically located in front of the pilot or one of the burner flames.
It is used as a safety device that insures a flame is present.

When a flame is present the sensor passes a small electrical current through the flame and tells the circuitry what to do.
If the sensor gets dirty the current passing through the flame is to weak for the circuitry to work properly.

To clean the flame sensor, disconnect power to the furnace, remove the flame sensor, clean it with some crumpled up aluminum foil or some very fine sandpaper or steel wool.
Reinstall it and reconnect the power to the furnace.




If my answer helped, please click Rate this Answer! below. Thanks!
  Reply With Quote
 
     
 
 
Old Jan 29, 2007, 08:48 AM   #29  
NorthernHeat
Heating & Air Conditioning Expert
NorthernHeat is offline
 
Join Date: Oct 2006
Location: IN
Posts: 1,355
NorthernHeat See this member's comment history on his/her Profile page.NorthernHeat See this member's comment history on his/her Profile page.
What is a pressure switch?

Pressure switch's are a safety device.
They insure the flue pipe and inducer draft blower motor are functioning correctly.

If the flue pipe becomes obstructed, or the inducer fails to start, the furnace will not ignite.
Also be aware, if the vacuum hose or vacuum ports become obstructed, or fill with water, the furnace will not start.

Often furnaces are installed with improper flue pipe sizes and can take a year or two for the problem to surface.

Sometimes the pressure switch can simply go bad and need replaced.



If my answer helped, please click Rate this Answer! below. Thanks!
  Reply With Quote
 
     
 
 
Old Jan 29, 2007, 08:56 AM   #30  
NorthernHeat
Heating & Air Conditioning Expert
NorthernHeat is offline
 
Join Date: Oct 2006
Location: IN
Posts: 1,355
NorthernHeat See this member's comment history on his/her Profile page.NorthernHeat See this member's comment history on his/her Profile page.
Where is the diagnostic light?

Diagnostic lights are typically found on the circuit board.
If the circuit board detects there is a problem the lights will begin to blink a code. ex... 3 blinks and a pause, then 3 blinks-pause again, and so on.

The codes are then located on one of the doors, the circuit board or in the blower compartment, describing the problem.

Note... on most furnaces when the power is turned off, these codes are lost, you will have to wait untill the furnace malfunctions again to retrieve the diagnostic code.




If my answer helped, please click Rate this Answer! below. Thanks!
  Reply With Quote
 
     


Question Tools Search this Question
Search this Question:

Advanced Search
Display Modes

 
Similar Sponsors

Similar Questions
Question Asker Topic Answers Last Post
blower kicking on/off LyleLeonard Heating & Air Conditioning 3 Jan 29, 2007 03:17 PM
no blower KJorg Heating & Air Conditioning 1 Jun 2, 2006 04:58 PM
Blower canadianguy Heating & Air Conditioning 5 Jan 18, 2006 10:27 AM
blower botmco Heating & Air Conditioning 3 Dec 21, 2005 02:50 PM
Blower won't come on... b_critical Heating & Air Conditioning 1 Aug 11, 2005 09:33 AM