Question
 
 
#1  
Old Jan 22, 2007, 08:24 AM
s246
New Member
s246 is offline
 
Join Date: Jan 2007
Posts: 1
s246 See this member's comment history on his/her Profile page.
Heat Pump not heating house -fan is running

We have a Ruud heat pump that is 12-13years old & as of the last few days, it does not seem to be heating the house very well but it has been very cold for this part of the country. It works well when the outside temp is above 50 degrees. It has been in the upper 30's and low 40's. We put on the emergency heat for awhile but when we did the fan stops.

Thank you.

Reply With Quote
 
     

Answers
 
 
Old Jan 22, 2007, 08:46 AM   #2  
Junior Member
rickdb1 is offline
 
Join Date: Mar 2006
Location: St. Louis
Posts: 186
rickdb1 See this member's comment history on his/her Profile page.
Quote:
Originally Posted by s246
We have a Ruud heat pump that is 12-13years old & as of the last few days, it does not seem to be heating the house very well but it has been very cold for this part of the country. It works well when the outside temp is above 50 degrees. It has been in the upper 30's and low 40's. We put on the emergency heat for awhile but when we did the fan stops.

Thank you.
Have the freon charge checked. It may be low. The outside fan will stop when the emergency heat is on. That's normal when the electric heat strips come on and you are no longer using the heat pump operation...Upper 30's to 40 degress should be no problem for the heat pump...
  Reply With Quote
 
     
 
 
Old Jan 22, 2007, 03:08 PM   #3  
Junior Member
Stubby74 is offline
 
Join Date: Jan 2007
Posts: 36
Stubby74 See this member's comment history on his/her Profile page.
Your symptoms are leaning to sounding like a Emergency Heat relay or Sequencer. Depending on your system, some companies have a control board that tells the fan to come one and if it doesnt tell your fan to come on then your emergency heat wont run. Kind of a safety feature. By saying it is heating fine until gets really cold sounds like your emergency heat not working properly...I would call tech out to check! Brian
  Reply With Quote
 
     

Bookmarks


Thread Tools
Display Modes

 
Similar Sponsors

Similar Threads
Question Asker Forum Answers Last Post
Heat Pump Fan does not run at all times Sarge23 Heating & Air Conditioning 2 Jan 21, 2007 07:23 AM
Lennox heat pump makes noise, slow condensor fan sloracs1 Heating & Air Conditioning 1 Dec 28, 2006 05:42 PM
Heat Pump compressor fan problem dontkillbill Heating & Air Conditioning 1 Jul 20, 2006 03:35 PM
Heat pump AHU fan runs continuously barker7 Heating & Air Conditioning 0 Jul 3, 2006 07:47 AM
running furnace fan without heat isleroyale Heating & Air Conditioning 5 Nov 29, 2005 05:19 AM