    Heat pump , in cooling cyce unit runs no cold air
    1970's heat pump Heil runs in cooling cycle, compressor intermediately runs for approximently 2 seconds, every 30 to 45 seconds, no cold air, all information wirering schematics serial numbers unreadablle or missing, charging ports and service valves was not visiable from service panells, my disanoticslow freon, run valve shutting compressor on and off, or compressor run capacitor faulty.
    acetc's Avatar
    acetc Posts: 1,004, Reputation: 79
    Ultra Member
     
    #2

    Sep 2, 2008, 08:21 PM
    It may be going off on a low pressure switch or overload in the compressor . You need to put gages on the unit as well as check the amp draw. There are service ports some where on the unit , Good luck, Mike

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Heat pump not cooling as well [ 2 Answers ]

We have a heat pump and replaced it 4-5 years ago when our old one died. Our home is well insulated and we keep it closed up during warm-hot weather. About a week ago it got very hot again, but not as hot as it's been earlier this year. We have cool air coming out of the vents with a normal force,...

Heat pump not cooling well [ 8 Answers ]

We have a heat-pump and had to have a new capacitor installed about 2 months ago, because the outside fan would not run. It's been working great ever since until yesterday. I noticed the tempature has elevated and the air flow seems good. I replace filter monthly, and put a new one in again. The...

Heat Pump runs but doesn't heat or cool. [ 4 Answers ]

I know this is pretty basic--but my older Rheem Classic IX (in FL) seems to be operating fine--except it stopped heating and I think, cooling. It seems to be running fine, without any obvious leaking. It just blows the same cool air on either setting. Where should I start? Are there fuses to look...

Carrier heat pump not cooling [ 2 Answers ]

Our Carrier heat pump is not cooling our house. This is the first time it has been on for cooling this year. The system is running outside and the system inside is running and cool to the touch, but nothing is coming out the vents. It sounds like the fan is running. The thermostat is set for 72...

Outside a/c unit runs when heat is on [ 1 Answers ]

We have Trane XB80 that's three years old. This past fall we installed a Hunter programmable thermostat model number 44360. The wiring on the thermostat was done correctly. We have natural gas heat. Our outside unit runs when we're using the heat. Is this supposed to happen and, if not, what could...


View more questions Search