Home > Home & Garden > Heating & Air Conditioning   »   Installed Honeywell RTH3100C and A/C kicks on after a few minutes of heat

 
Question Tools Search this Question Display Modes
Question
 
 
#1  
Old Jan 25, 2008, 06:05 PM
StinkyRose
New Member
StinkyRose is offline
 
Join Date: Jan 2008
Posts: 5
StinkyRose See this member's comment history on his/her Profile page.
Installed Honeywell RTH3100C and A/C kicks on after a few minutes of heat

I have a single stage heat pump. Electric.

I'm not sure what I have done wrong. I have the following wires:

yellow
white
red
green

According to the installation manual, I have installed them in the following locations:

yellow - Y
white - AUX
red - R
green - G

I have also added a jumper from E to AUX, which was also in the manual.

The heat will turn on and blow warm for about 3-5 minutes, then my zoning control panel will switch to cool and it will blow the air conditioner.

It has to be my wiring! Can anyone help?

Thanks!

Reply With Quote
 
     

Answers
 
 
Old Jan 25, 2008, 08:34 PM   #2  
hvac1000
Heating & Air Conditioning Expert
hvac1000 is offline
 
hvac1000's Avatar
 
Join Date: Aug 2005
Posts: 4,733
hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.
Do you also have a electric furnace?

Did you do page 16 and 17 of the manual?

Below is a copy of your manual with the pages listed.

http://customer.honeywell.com/techli.../69-1889EF.pdf

Zone control panel could be causing the problem also. The thermostat and zone control might be incompatable.
  Reply With Quote
 
     
 
 
Old Jan 26, 2008, 05:01 AM   #3  
NorthernHeat
Heating & Air Conditioning Expert
NorthernHeat is offline
 
Join Date: Oct 2006
Location: IN
Posts: 1,355
NorthernHeat See this member's comment history on his/her Profile page.NorthernHeat See this member's comment history on his/her Profile page.
You don't have enough wires at thermost for a heat pump. Where is the reversing valve control wire, usually blue or orange. Are you sure this is a heat pump?
  Reply With Quote
 
     
 
 
Old Jan 26, 2008, 05:39 AM   #4  
StinkyRose
New Member
StinkyRose is offline
 
Join Date: Jan 2008
Posts: 5
StinkyRose See this member's comment history on his/her Profile page.
I'm positive it's a heat pump. There is also no orange going to the zone control panel.

But now I have a new problem! The A/C does not kick on anymore after I switched the Y wire from the Y terminal to the Y1 terminal.

But now the heat will not shut off! After the thermostat is satisfied, it just keeps running. The thermostat clicks off and does not say "heat" anymore, but the furnace only shuts off if I manually turn off the thermostat or remove it from the wall.

Here is my current wire configuration:

white = W/B
yellow = Y1
Red = Rh
Green = G

There is a jumper between Rh and Rc. It's a Hunter 44155C.

I said E and AUX before, but I think I was confused after reading so many answers on here. So disregard that.

Any ideas?
  Reply With Quote
 
     
 
 
Old Jan 26, 2008, 05:43 AM   #5  
NorthernHeat
Heating & Air Conditioning Expert
NorthernHeat is offline
 
Join Date: Oct 2006
Location: IN
Posts: 1,355
NorthernHeat See this member's comment history on his/her Profile page.NorthernHeat See this member's comment history on his/her Profile page.
Is this a Carrier or Bryant sytem? Perhaps the infinity system?
  Reply With Quote
 
     
 
 
Old Jan 26, 2008, 05:48 AM   #6  
StinkyRose
New Member
StinkyRose is offline
 
Join Date: Jan 2008
Posts: 5
StinkyRose See this member's comment history on his/her Profile page.
Well, I spoke too soon. The A/C just kicked on after the heat ran for a few minutes.

So last night the heat would not shut off and today my A/C kicking on problem is back!!

It is a Carrier unit.

I had a technician come Thursday and he told me it is definitely the thermostat, but he couldn't fix it and told me it was the wrong thermostat for a heat pump. I looked it up and this thermostat will in fact work with a single stage heat pump, I just have it wired incorrectly.

I'm trying to avoid calling them again because they charge me $80 just to come out here.
  Reply With Quote
 
     
 
 
Old Jan 26, 2008, 05:58 AM   #7  
hvac1000
Heating & Air Conditioning Expert
hvac1000 is offline
 
hvac1000's Avatar
 
Join Date: Aug 2005
Posts: 4,733
hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.
Make your life simple.

First post you state it is a Honeywell thermostat. (Installed Honeywell RTH3100C)

Fourth post down you said it is a Hunter. (It's a Hunter 44155C)

We know you do not know what you are doing and we are trying to help you but it seems you have no idea what thermostat you have to start with.

This problem is probably way over your head and it is impossible to see exactly what you have because we are not there to see the system zone control, wiring,a programed settings.

My advice is to call back the professional and have them correct the problem before you burn up a zone control board, thermostat. or both.
  Reply With Quote
 
     
 
 
Old Jan 26, 2008, 05:59 AM   #8  
NorthernHeat
Heating & Air Conditioning Expert
NorthernHeat is offline
 
Join Date: Oct 2006
Location: IN
Posts: 1,355
NorthernHeat See this member's comment history on his/her Profile page.NorthernHeat See this member's comment history on his/her Profile page.
They should come back under a warranty. I'm not sure your tech new what he was doing. Depending on the zone control you have that system may or may not work fine with the simplest of heat/cool thermostats. If you have what I think you have. Set up the thermostat for siple single stage heat/cool. (not H.P.) also remove the jumper from E to aux. Just W, Rh-Rc, Y and G. The zone control board should do the rest.
  Reply With Quote
 
     
 
 
Old Jan 26, 2008, 06:07 AM   #9  
StinkyRose
New Member
StinkyRose is offline
 
Join Date: Jan 2008
Posts: 5
StinkyRose See this member's comment history on his/her Profile page.
You know what, you're right - I did change thermostats. I got the new Honeywell after the technician told me the Hunter was not the right one for a single stage heat pump. That one didn't work either (hence my post last night), so I went back to the Hunter.

Sorry for the confusion, but I am going to stick with the Hunter and try to make it work.

I should point out that the Hunter worked just fine until we had a power surge a little over a week ago. I think I'll make a new post asking for info about the Hunter so it's in my title.

Thanks!! And I will certainly call back the technician but not if I can get this to work before Monday.
  Reply With Quote
 
     


Question Tools Search this Question
Search this Question:

Advanced Search
Display Modes

 
Similar Sponsors

Similar Questions
Question Asker Topic Answers Last Post
Wiring Honeywell RTH3100C Bill Hudgins Heating & Air Conditioning 0 Nov 6, 2007 04:05 PM
Wiring Honeywell RTH3100C thermostat foxwood Heating & Air Conditioning 0 Nov 4, 2007 09:58 AM
Honeywell rth3100c thermostat wireing RANDYMO Heating & Air Conditioning 0 Nov 1, 2007 11:24 AM
Replacing old heat pump thermostat with Honeywell RTH3100C Garnerean Heating & Air Conditioning 1 Mar 14, 2007 12:00 AM
Honeywell RTH3100c Wiring Question bailsmb Heating & Air Conditioning 1 Sep 22, 2006 02:41 PM




Copyright ©2003 - 2007, Ask Me Help Desk.
All times are GMT -8. The time now is 01:11 PM.

Content Relevant URLs by vBSEO 3.0.0 RC6 © 2006, Crawlability, Inc.