    Wulff's Avatar
    Wulff Posts: 2, Reputation: 1
    New Member
     
    #1

    Nov 24, 2007, 11:15 PM
    My heat pump AC works but not on heating cycle
    I live in a 2-story house in AZ and there are 2 Lennox (sic?) heat/AC pumps, one for each floor... it has 2 Honeywell TH8000 thermostats. Last winter there wasn't any problems but tonight it started getting cold so I turned it from cool setting to heat, I can hear relays in the TS click and it says "heat on" but nothing happens, I checked both TS and they both are doing that! I can turn it to the cool setting and turn the TS below the inside temp and the AC will come on okay so the heat pumps/AC units are running (getting power) I turned them off for awhile but no dice!
    Right now the inside temp it 71 and I have them both set for 74 and nothing!
    Being in the desert there isn't any 'backup' emergency heating all the heating/cooling is performed with the heat pumps only.
    Any ideas?
    wmproop's Avatar
    wmproop Posts: 3,749, Reputation: 91
    Ultra Member
     
    #2

    Nov 25, 2007, 12:45 AM
    Is the h/p not comeing on at all? Is th blower working in heat mode,if heat pump is running,and blower running,check the copper line the biggest one,, that comes from the heatpump into the airhandler from outside is it hot ?cold? Or what? Check and let us know more detales,the bigger copper line is cold in a/c mode and hot in heat mode.
    Wulff's Avatar
    Wulff Posts: 2, Reputation: 1
    New Member
     
    #3

    Nov 25, 2007, 11:57 AM
    No the H/P only runs if I put it into cool mode, ditto for the blower (in heat mode if I go to manual fan mode I can turn on the blower but no heat comes out).
    Something I noticed is when I turn the upstairs onto heat once the relay closes I can hear what sounds like a small motor (or humming) coming from the attic.. it isn't the blower of course but could it be since I haven't used the heat portion of the system since last April it could be stuck?
    It wouldn't seem like both upstairs and downstairs would happen to do that at the same time!
    Oh, one more thing.. I had the TS set for heat and went out and manually pushed in the heat pump relay (outside) on one of the units.. don't worry I am careful as I work around high voltage machines in my job.. anyway I held it closed and let it run for a few minutes figuring if it was in heat mode I would feel cool air coming out (as it removed to cold from inside) but it was warm meaning it was removing heat from inside (right?) so it must be stuck in cooling mode...
    Oh, thanks very much for responding!

Not your question? Ask your question View similar questions

 

Add your answer here.


Check out some similar questions!

Heat Pump defrost cycle [ 1 Answers ]

Hopefully my question isn't redundant. Earlier this year I changed my thermostat from a manual to a programmable thermostat. The cooling and heating aspects seem to work fine but I have noticed that during the defrost cycle the aux heat doesn't appear to come on since I changed the thermostat. ...

Coleman Evcon D.E.S. II Heat Pump- works intermittently [ 1 Answers ]

She's an old one... I'm guessing the late 70's or 80's, but since I've lived here (4years) it seems to work for a while, but then stop... I hear a fan blowing, but it's cold air. Then I look at the t'stat and the red emergency light is on... cold air coming out of the vents. I look at the unit...

Heat pump not cooling or heating properly [ 2 Answers ]

I am having a problem with my Rheem heat pump. The indoor unit seems to be fine and the blower motor is running. The outside unit seems to be the problem. The fan only runs part of the time sometimes not kicking on at all other time kicking on for several minutes then kicking off before the temp is...

Heat pump blower does not cycle off. [ 4 Answers ]

My problem I believe is with the blower control on a heat pump. With the thermostat in COOL or AUTO, the outdoor unit stops as expected when the temperature setpoint is reached. But the blower does not stop running. It continues to run as if it's in a manual run control. If the breaker to...

Heat Pump not heating house -fan is running [ 2 Answers ]

We have a Ruud heat pump that is 12-13years old & as of the last few days, it does not seem to be heating the house very well but it has been very cold for this part of the country. It works well when the outside temp is above 50 degrees. It has been in the upper 30's and low 40's. We put on the...


View more questions Search