Question
 
 
#1  
Old Dec 4, 2006, 07:43 AM
roireau
New Member
roireau is offline
 
Join Date: Dec 2006
Posts: 1
roireau See this member's comment history on his/her Profile page.
Gravity Floor furnace

I have a pilot light lit and the thermostat is connected, tryed switching 2 wires at thermostat but this did nothing.
What next please

Reply With Quote
 
     

Answers
 
 
Old Dec 4, 2006, 09:59 AM   #2  
Heating & Air Conditioning Expert
hvac1000 is offline
 
hvac1000's Avatar
 
Join Date: Aug 2005
Location: Ohio
Posts: 11,320
hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.
If this floor unit has a non 100% gas shut off and it will not lite the main burner it is probably the thermocouple. If it is a 100% gas shut off unit you could never get the pilot to stay on if it was a bad thermocouple. probably a bad thermocouple or lack of voltage supplied to the gas valve. I have not serviced a floor unit for over 30 years. I am suprised they are still around they are not very energy efficient.
  Reply With Quote
 
     
 
 
Old Dec 4, 2006, 10:25 AM   #3  
Über Member
labman is offline
 
Join Date: Feb 2003
Location: Northern US
Posts: 10,646
labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.
What do you mean switching the wires at the thermostat? Did you mean touching them together? If that didn't work, can you measure the voltage if any between them? If no voltage, follow the wires back to the furnace looking for breaks. Try jumpering them at the furnace. If you have the voltage on the name plate, and the gas valve doesn't open, it is bad.

Floor furnaces are simple and reliable. Find and fix this problem, and it may go for years without any trouble. If you live where you don't use heat much, it might not be worth replacing it. Look at all the problems people are having with modern furnaces, blowers, and unrepairable control boards.
  Reply With Quote
 
     
 
 
Old Dec 4, 2006, 01:42 PM   #4  
Heating & Air Conditioning Expert
hvac1000 is offline
 
hvac1000's Avatar
 
Join Date: Aug 2005
Location: Ohio
Posts: 11,320
hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.
Hi labman. I agree they last a long time but who can afford to feed the fuel into those 60% efficient old style floor furnaces. I also agree with your ststement about the new furnaces being trouble prone. Looks like you will have to pay out the nose for fuel or pay out the nose for parts and labor for the newer furnaces. LOL No win situation I guess. I retired at 48 from my small 37 man heating corporation. I now due field studies/repair diag. for two major hvac manufactures for some fun. Most problems with new equiptment has to do with proper install. Years ago all you had to due was turn them on after the install but today you need to check the co and flue temp just for starters and most hvac companys do not due that. In fact most companys do not have the proper equiptment to check them to start with. This has always been a crazy business and now with the new equiptment it is just that much more fun. I am glad I am not out in the field every day like when I was younger.
  Reply With Quote
 
     
 
 
Old Dec 4, 2006, 02:10 PM   #5  
Über Member
labman is offline
 
Join Date: Feb 2003
Location: Northern US
Posts: 10,646
labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.
When I went with a new furnace 10 years ago, I saved some money by doing the strong back and weak mind stuff myself. The contractor insisted on doing the start up. Likely a good compromise for a DIY. I had no idea how much tuning the system would take. It is a Bryant 80+. 80% at the high firing rate, and more at the low rate. The only trouble was the circuit board was bad one fall on start up. Do you think lightening fries them? After paying $300 for a new one, I hardwired in a surge protector.
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login



Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes
Ask your question or search...



Similar Threads
Gravity
(3 replies)
floor furnace
(1 replies)
Old Floor Furnace
(2 replies)
Gravity
(3 replies)
Gravity
(3 replies)

Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page
Search this Thread

Advanced Search

Bookmarks





Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 11:50 PM.