    Goodmans furnace flames keep going out
    When I start my furnace the burners stay on for 5 to 10 seconds then go out.I check the flame sensor its OK ?
    tsa7man's Avatar
    tsa7man Posts: 154, Reputation: 9
    Junior Member
     
    #2

    Oct 17, 2007, 09:53 AM
    My question to you, is how did you check the flame sensor ? The correct way to check one is with a volt meter set for ohms ( and or continuity ) and with one lead from your meter on the wire end (disconnected ) and with the other meter probe ONLY touch the outer 1 inch of the flame rod, does the meter register a beep, proving continuity ? DO NOT RUB the probe on the flame proving rod to check, because in the flame rectification process, the flame does not rub the rod to prove flame. Usually, corrosion is the cause of a furnace not proving flame through the flame rod ( cleaning it carefully with rough steelwool or sand paper, will clean the corrosion off it )... BUT if it tests OK the cause could be a bad control, not recognizing the flame sense from the rod.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Goodmans G-Shot 3003cc [ 1 Answers ]

Hi. Does anyone have the Drivers for the Goodmans G-Shot 3003cc Digital Camera? I need the Video and Digital Camera drivers and I can't find my disk anywhere! I've looked on the not very useful goodmans website and there aren't any drivers. I had the G-Shot 2025 TFT and I tried those...

What they had, went up in flames [ 6 Answers ]

My aunt has a really bad drinking problem and she just had a fire in her house this week that destroyed EVERYTHING... I think she's going to try and commit suicide again because of all her problems and now she has no home and already owes a lot in debt from her husband buying really expensive stuff...

Goodman furnace flames out when cold [ 8 Answers ]

Goodman GMPO75-3 ser9911605881 . When warmed up runs OK . Cold the DI fan runs then HSI glows,gas valve opens and it lights with woof woof and goes out in 5 secs . Cycles again and it might start or go on third try. I polished the fire rod, set GV to 3.5 ins then changed GV. 24 volts at the GV...

NG furnace flames out each restart [ 1 Answers ]

100K BTU ng,Honeywell 1982 furnace. New filters, good intake(I think). Has worked fine until last 2.5 weeks. Pilot light is fine, main gas ignites and will stay lit for about 20 seconds. The honeywell hi/lo limit switch clock turns to main fan, sometimes it will reach the fan on temp, but...