    tcassil's Avatar
    tcassil Posts: 5, Reputation: 1
    New Member
     
    #1

    Nov 29, 2006, 03:11 PM
    Goodman heating unit problems
    Hello, I have a Goodman :( heating unit in the house that I moved into model GPM100-4.
    When the exhaust fan comes on to clear out the system before the unit will fire up. It makes a clicking sound. I have learned that it's trying to pull a vacuum from the exhaust fan to a safety switch. If I suck on the vacuum hose it will make the switch and the clicking stops unit runs fine. If I don't, it may click fifty times or click until it times out. I have replaced the pressure switch, hose and fan, but still has not changed anything. Just wonder if anybody else has seen this?
    Thanks,
    Tim
    NorthernHeat's Avatar
    NorthernHeat Posts: 1,455, Reputation: 132
    Ultra Member
     
    #2

    Nov 29, 2006, 05:38 PM
    There is an obstruction in the vent most likely. Read some of my other posts, pertaining to goodman furnaces.
    tcassil's Avatar
    tcassil Posts: 5, Reputation: 1
    New Member
     
    #3

    Nov 29, 2006, 06:14 PM
    I have read your other post and have check everything for an obstruction. The hose, the pressure switch, and where the hose attaches to the exhaust fan. I took off the exhaust vent and checked it, it's clear and even tested it with the vent off and it still had the same issuses.
    tcassil's Avatar
    tcassil Posts: 5, Reputation: 1
    New Member
     
    #4

    Dec 2, 2006, 05:17 PM
    Might this be an issue with the mother-board cutting out a motor relay before the motor gets started?
    NorthernHeat's Avatar
    NorthernHeat Posts: 1,455, Reputation: 132
    Ultra Member
     
    #5

    Dec 3, 2006, 05:27 AM
    If everything is clear and the draft inducer is running I would replace the pressure switch
    tcassil's Avatar
    tcassil Posts: 5, Reputation: 1
    New Member
     
    #6

    Dec 10, 2006, 08:03 PM
    Ok, I changed the pressure switch and it still clicks about 50 times to start the fan:confused: . I can still suck on the rubber hose and the fan starts right up. What should be my next step?

    Thanks,
    Tim
    turnerwest's Avatar
    turnerwest Posts: 8, Reputation: 2
    New Member
     
    #7

    Dec 10, 2006, 09:34 PM
    Quote Originally Posted by tcassil
    Hello, I have a Goodman :( heating unit in the house that I moved into model GPM100-4.
    When the exhaust fan comes on to clear out the system before the unit will fire up. It makes a clicking sound. I have learned that it's trying to pull a vacuum from the exhaust fan to a safety switch. If I suck on the vacuum hose it will make the switch and the clicking stops unit runs fine. If I don't, it may click fifty times or click until it times out. I have replaced the pressure switch, hose and fan, but still has not changed anything. Just wonder if anybody else has seen this?
    Thanks,
    Tim
    Tim, you say it's a house you moved into... How old is the furnace and has anyone changed or touched the furnace flue? Eric
    tcassil's Avatar
    tcassil Posts: 5, Reputation: 1
    New Member
     
    #8

    Dec 10, 2006, 10:36 PM
    The furnace is about 4 years, this is my second winter in this house. As far as the flue, I have taken it off and ran it with out it to see if this changed anything (only for a short amount off time and then put it back on) but even with the flue off it's doing the same thing. If it's doing it without the flue, would that show that the flue is not blocked.
    Last winter it made the clicking sound three or six times to start up. I just thought that was bad. Now it can do it for 2 or 3 minutes, before I get off my butt and go suck on the pressure switch hose. It's kind of a running joke with my faimly, but it's starting to suck(haha). I'm afraid that it's going t leave us without any heat some day soon.
    Thanks,
    Tim
    labman's Avatar
    labman Posts: 10,580, Reputation: 551
    Uber Member
     
    #9

    Dec 11, 2006, 04:53 AM
    Have you identified just which component is clicking? Sometime you can tell if a relay is chattering by holding your hand on it. Note, sometimes relays have hot contacts on or around them.

    Have you tried a new rubber hose?
    NorthernHeat's Avatar
    NorthernHeat Posts: 1,455, Reputation: 132
    Ultra Member
     
    #10

    Dec 11, 2006, 04:20 PM
    Is it 90% efficient and is it on LP?
    accurate air's Avatar
    accurate air Posts: 1, Reputation: 1
    New Member
     
    #11

    Dec 25, 2006, 09:35 PM
    Quote Originally Posted by tcassil
    Hello, I have a Goodman :( heating unit in the house that I moved into model GPM100-4.
    When the exhaust fan comes on to clear out the system before the unit will fire up. It makes a clicking sound. I have learned that it’s trying to pull a vacuum from the exhaust fan to a safety switch. If I suck on the vacuum hose it will make the switch and the clicking stops unit runs fine. If I don't, it may click fifty times or click until it times out. I have replaced the pressure switch, hose and fan, but still has not changed anything. Just wonder if anybody else has seen this?
    Thanks,
    Tim
    On the inducer housing where the vacuum hose connects the small barbed fitting I have seen that there is a ball inside at back of that fitting the inner side which is acting as a check vavle that sometimes gets corroded and seizes causing the pressure switch not to open I have in the past drilled this fitting out veryy carefullly and removed this ball check vavle you will probably have to remove the inducer assembly to check & do this. Hope this solvesyour problem [email protected]
    NorthernHeat's Avatar
    NorthernHeat Posts: 1,455, Reputation: 132
    Ultra Member
     
    #12

    Dec 26, 2006, 05:35 AM
    Quote Originally Posted by accurate air
    On the inducer housing where the vaccum hose connects the small barbed fitting I have seen that there is a ball inside at back of that fitting the inner side which is acting as a check vavle that sometimes gets corroded and seizes causing the pressure switch not to open i have in the past drilled this fitting out veryy carefullly and removed this ball check vavle you will probably have to remove the inducer assembly to check & do this. hope this solvesyour problem [email protected]
    Sorry. There is no check valve in any inducer draft blower that I have ever seen. You are right about it rusting closed though. Just make sure the flue vacuum hose and ports are open and clear. If you can't find the problem the vacuum switch may be bad.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Ac/heating unit [ 3 Answers ]

Dear Sir, I have a heating unit it will work sometime but it will not turn on sometime like the other night when it got below in the low 50 it came on for two day's mow it will not come on for a few more day's when it drop's below in the low 50 it work's sometime then not off and on can you help me...

AC/Heating Unit Combo HELP [ 2 Answers ]

We have, I believe, a 2-ton Lennox AC/Heating roof-top unit. Lately, the unit was having trouble cooling the house, which is about 1,500 - 1,700 sq ft. We could set the thermostat to 68 degrees, and the house would only cool down to 80 degrees. Yesterday, the unit stopped blowing cold air...

Location for heating a/c unit [ 1 Answers ]

In a two story house is there any reason not to put the only heating and a/c unit on the second floor? Thank you

AC/Heating unit will not come on [ 4 Answers ]

I attempted to replace an old York programmable thermostat with a Hunter thermostat. After installing the Hunter thermostat, my unit will now not come on. I checked the circuit breaker and it is on. What else do I need to check? Please tell me that I didn't blow my unit. Any help or suggestions...


View more questions Search