Ask Me Help Desk

Ask Me Help Desk (https://www.askmehelpdesk.com/forum.php)
-   Heating & Air Conditioning (https://www.askmehelpdesk.com/forumdisplay.php?f=150)
-   -   Goodman heater gmp075-3 3-blinks on board (https://www.askmehelpdesk.com/showthread.php?t=271721)

  • Oct 20, 2008, 08:03 PM
    tommyd
    Goodman heater gmp075-3 3-blinks on board
    I have a goodman heater, I have cleaned out the chiminey pipe, replaced the pressure switch and it still will not ignite, can anyone point me in the right direction to repair this?
    Tom
  • Oct 21, 2008, 03:48 AM
    hvac1000
    Find the wiring diagram and blink legend on the diagram on the back side of the blower door panel. Next check the furnace component that it says is the problem.

    3 blinks is


    End switch closed without inducer on.

    CHECK

    Venter end switch for proper operation.

  • All times are GMT -7. The time now is 04:27 AM.