Ask Experts Questions for FREE Help !
Ask
    slreno's Avatar
    slreno Posts: 2, Reputation: 1
    New Member
     
    #1

    Oct 17, 2008, 06:31 AM
    Goodman furnace won't stay lit
    I have a goodman furnace that goes like this.
    Inducer fan comes on, 10 secs later glow lights up,
    10 secs later get blue flames
    10 secs later blue flames goes out. Repeats 3 times
    I have replaced the flame sensor still same problem
    But here is the thing. I am only getting 10 volts to the first rollout sensor before it calls for gas. Then when it calls for gas and lights it goes to 0.00

    I have also jumped the pressure switch and that didn't cure the problem. I also removed the exhaust vent (just to see if it would run with it disconnected making sure there where no obstructions in chimney) didn't fix the problem.

    I have boiled it down to a board or gas valve. Wouldn't it have to be the board since I am only getting 10 volts to the valve and rollouts?
    slreno's Avatar
    slreno Posts: 2, Reputation: 1
    New Member
     
    #2

    Oct 17, 2008, 07:07 AM

    Edit I do have 26 volts before and after the safety rollouts in sequence to the gas valve when the ignitor is red.
    The I have this.
    I have 26 volts from the rollout to the gas valve and nothing coming from the second light blue wire going back down to the board at any time.
    Should there be voltage on this light blue wire at any time?

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Goodman GMP100-3 Furnace won't Stay On. [ 14 Answers ]

Hello, I have a Goodman Furnace (model # GMP100-3). The furnace will not stay running. Here is the sequence of events for two different scenarios that are occurring. Scenario 1 1. Thermostat Calls for Heat 2. Inducer starts 3. Pressure switch closes 4. Heating element glows 5. Burners...

Goodman furnace comes on but won't stay lit [ 6 Answers ]

Hi my goodman furnace tries to lite but something cuts the gas right back off. Is that the gas regulator? And can I just replace the module on the front of it or do I have to replace the whole regulator? Thanks Brian

Furnace won't stay on [ 4 Answers ]

I have a gas pump furnace that has been switched over to propane prior to me moving in. Replaced filters and thermostat, checked all fuses and junction box. a/c works and fan only works but when I turn it to heat - I get nothing. I removed panel and reset the switch - it stayed on for about 3-4...

Goodman Furnace won't stay running [ 3 Answers ]

I have a goodman furnace that won't stay on.. the glow plug comes on and ignites the heat box, it will run then shut off... after it gets to desried heat,, then when you try to get it to run again it's like it shuts down after igniter being lit for about 10 secs, I've replaced batteries in...

Goodman Furnace Issue - Heater won't work, no fire [ 1 Answers ]

My Goodman heater won't fire up. When I turn the heat on, the sequence of events: 1) Small fan at top section turns on. 2) Heating element turns on, bright red. The system sounds like it is trying to turn on. 3) Then the bright red goes off. The fire does not light. The fan does not start 4)...