    Oct 11, 2007, 07:24 AM
    Goodman furnace induced draft motor
    On a call for heat the draft motor starts but the air proving switch does not close. I replaced it with the same result. Everything works normally if I close the switch manually with my own air pressure. Someone told me that somethimes the motor, due to age (this one is 13 years) will not spin fast enough to produce enough pressure to close the switch. Any help would be appreciated.
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Oct 11, 2007, 11:42 PM
    Check for any restrictions that would not let enough pressure to activate the control.
    acetc's Avatar
    acetc Posts: 1,004, Reputation: 79
    Ultra Member
     
    #3

    Oct 12, 2007, 05:07 PM
    The fitting that the tubing connects to on the induced draft blower housing may be fouled, this is common, run a small wire or drill bit through it to insure its not restricked, Good luck, Mike
    T-Top's Avatar
    T-Top Posts: 1,871, Reputation: 100
    Ultra Member
     
    #4

    Oct 12, 2007, 06:44 PM
    If your vent pipe is restricted it won't close. If it's a 90% furnace(vented with PVC) you may have had a bird build a nest in the vent pipe. Is your furnace vented with PVC or metal? What brand is it?

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Goodman furnace GMNT080-4 furnace runs good for a while then has to be manually reset [ 5 Answers ]

I have a Goodman GMNT080-4 (90%). I'm having the same problem As Streatherg did back in the Nov 2006 question. I reviewed his article and tried Every thing on there but seems to be doing the same thing. The furnace kicks on for about an hour then locks out and has to be manually reset threw...

Goodman Inducer Motor [ 18 Answers ]

I have a Goodman Gas Furnace installed in 1997 and have been experiencing the following problems: The usual run for the furnace has been inducer motor on, ignition (with flames), and then the blower motor comes on. I have been having the inducer motor come on, run for about three minutes,...

Goodman AC/Furnace: condenser not coming on after installation of new blower motor [ 6 Answers ]

Have and outside Goodman AC unit and Goodman furnace (inside duh!). Anyhoo, after installing new blower motor the AC unit will not kick on. Have reset outside breaker, and double checking wiring on controller board on furnace, noticed one blue wire was disconnected, reconnected that and still not...

Induced draft blower problem? [ 2 Answers ]

We have a Nordyne G6RC Series 90+ Upflow Condensing Gas Furnace. I think its about 8 years old, but I'm not exactly sure. It seems to be having a problem with the induced draft blower. What's happening is when the thermostat calls for heat, the induced draft blower won't come on, and then I...


View more questions Search