Question
 
 
#1  
Old Oct 25, 2007, 10:33 AM
tsteiden
New Member
tsteiden is offline
 
Join Date: Oct 2007
Posts: 4
tsteiden See this member's comment history on his/her Profile page.
Goodman Furnace - brand new - won't start

Installed this summer, A/C works fine.

First time I started the furnace (last week) it started fine, then shut off shortly (15 min. later).

No led errors are reading on the board. After shutting off power to re-start the start sequence (it shuts down after 3 tries), the inducer motor starts, the pilot glows, but it will not lite.

Waited 2 days (it wasn't cold enough to need it) then tried again - same thing - it starts fine, runs 15 min or less, then shuts down and will not re-start.

What could it be? I read a post about matching the settings on the thermostat for the heat anticipator - how would you do that on a programable?

Any other ideas? I'm stumped.

Reply With Quote
 
     

Answers
 
 
Old Oct 25, 2007, 12:00 PM   #2  
Heating & Air Conditioning Expert
hvac1000 is online now
 
hvac1000's Avatar
 
Join Date: Aug 2005
Location: Ohio
Posts: 11,303
hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.
Your furnace is new. Call the contractor that installed it because it is under warrenty.
  Reply With Quote
 
     
 
 
Old Oct 25, 2007, 12:10 PM   #3  
New Member
tsteiden is offline
 
Join Date: Oct 2007
Posts: 4
tsteiden See this member's comment history on his/her Profile page.
I installed it myself
  Reply With Quote
 
     
 
 
Old Oct 25, 2007, 04:50 PM   #4  
Heating & Air Conditioning Expert
hvac1000 is online now
 
hvac1000's Avatar
 
Join Date: Aug 2005
Location: Ohio
Posts: 11,303
hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.hvac1000 See this member's comment history on his/her Profile page.
The heat anticipator should not cause the furnace to run. The heat anticipator is set up to make sure the thermostat does its job correctly in regards to range. When it turns on at 70 it will be 70 and when it turns off at 75 it will be 75. Most thermostats have a adjustment but you will need to get a total amp reading when the furnace is running. It takes into account the gas valve draw,wire draw etc.

You may try to clean the sensor which could have become dirty during the install. If you never had your furnace inspected and checked over after you installed it now is the time to do so.
  Reply With Quote
 
     
 
 
Old Oct 25, 2007, 06:19 PM   #5  
Ultra Member
T-Top is offline
 
Join Date: Nov 2006
Posts: 1,159
T-Top See this member's comment history on his/her Profile page.
If you are running LP gas did you convert it over for it. The furnace is set up for NG from the factory.
  Reply With Quote
 
     
 
 
Old Oct 25, 2007, 07:56 PM   #6  
New Member
tsteiden is offline
 
Join Date: Oct 2007
Posts: 4
tsteiden See this member's comment history on his/her Profile page.
Thanks for the replies. No, I'm using NG, not LP.

Yes, I WILL have someone look at it if no one here has anymore ideas of what could be wrong.
  Reply With Quote
 
     
 
 
Old Oct 25, 2007, 08:29 PM   #7  
Über Member
labman is offline
 
Join Date: Feb 2003
Location: Northern US
Posts: 10,646
labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.
Read through the sticky at http://www.askmehelpdesk.com/heating...ons-58313.html

Check the terminals for power to the gas valve. If it has power, and the gas isn't on, it is bad.
  Reply With Quote
 
     
 
 
Old Oct 27, 2007, 01:16 PM   #8  
New Member
tsteiden is offline
 
Join Date: Oct 2007
Posts: 4
tsteiden See this member's comment history on his/her Profile page.
Turns out that I neglected to remove a plug from the condensate reservoir before I attached the drain hose. That caused a pressure switch to be disabled when it filled up so the gas valve wouldn't open.

Anyway, it works now. Thanks for the help.
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
My Brand New Goodman 3tn Heat Pump only pushes freon for 5 seconds and stops. Why ?
(2 replies)
Goodman furnace GMNT080-4 furnace runs good for a while then has to be manually reset
(4 replies)
Furnace Brand Suggestions
(1 replies)
Goodman Furnace will not start
(4 replies)
furnace brand and BTUS
(3 replies)

Search this Thread

Advanced Search

Bookmarks

Sponsors



Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 05:56 PM.