    Goodman Furnace Blower won't turn off NO Heat
    My sister-n-law has a Goodman GUPI075-3 furnace. The blower will not turn off even if thermostat is off. Does not ignite either.
    If you cut the electric and turn it off, when you turn it back on, the inducer motor starts and runs for about 3 seconds and then the blower turns on immediately. Never tries to ignite.
    ballengerb1's Avatar
    ballengerb1 Posts: 27,378, Reputation: 2280
    Home Repair & Remodeling Expert
     
    #2

    Feb 13, 2011, 12:28 PM

    There should be a small peep hole on the front panel which lets you look inside to see a code light. The color and blinking of the light is then compared to a chart inside that removable panel, it tell you what's wrong
    onesaw's Avatar
    onesaw Posts: 2, Reputation: 1
    New Member
     
    #3

    Feb 13, 2011, 12:36 PM
    This furnace looks pretty old. Don't see any lights anywhere. Is this a generic response or are you familiar with this specific model? Thanks
    T-Top's Avatar
    T-Top Posts: 1,871, Reputation: 100
    Ultra Member
     
    #4

    Feb 13, 2011, 06:42 PM
    Most systems that use a inducer motor will have a control board that has a diagnostic light that blinks on system failure. You may have to remove the blower door and tape off the door safety switch, make the system call for heat to get the code. I know this is a generic response also but with out knowing if the pressure switch is closing --or if the main limit is open--or if the ignitor is working-- and so on.Its hard to say. If no Light flashing and you can use a volt meter we can walk you through it.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

45692-001 blower control board will not turn blower on in either heat or cooling mode [ 2 Answers ]

Armstrong G1N80 furnace blower control board will not turn on fan at all. Not in heat or cooling mode. I can hear a click when fan should be energized, but no fan startup. Pigtailed the fan hot and neutral,and fan works fine. Is this just a blower control board problem, or something else? We had...

Goodman package unit blower won't turn off [ 0 Answers ]

Blower would not work on heat or ac. Discovered one of the 60amp breakers was not working. Replaced it. Heat and blower would then come on but even when the temp got to the thermostat set, the blower would not shut off. I replaced the thermostat and it would still not shut off. I believe the...

Goodman furnace will ?heat motor? And blower motor will run but not at same time [ 2 Answers ]

I have a 2 year old Goodman, gas, no heat pump. There is a flashing LED that blinks once ever 4 seconds. Also, blower motor does not stay on always. We did smell something like an electrical burn. I'm guess my blower motor is fried?

Heat blower does not turn - Air Handler does not turn on for heat [ 7 Answers ]

I have an Energy Kinetics System 2000 boiler. It is hooked up to two different zones (two different air handlers). Zone 1 (main house) when turned on at the thermostat clicks and calls for heat, the boiler starts for a bit but the fan/blower never kicks on. Zone 2 (master bedroom) works just...


View more questions Search