    Goodman Airhandler Split Unit
    I have a Goodman Airhandler Split Unit and my blower on one of the units will not cut off. I have changed the relay switch on both units. Switched the thermostats around and still it will not cut off. I can turn the thermostat off and it will constantly blow. I have to cut the main breaker off just to cut the one unit off. It will heat and cool but will not cut off. Please help!
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Dec 7, 2009, 12:25 AM
    Your problem is in the blower control circuit since that is the only item that controls the blower with the exception of a heat style air handler and then the sequencer can short the blower control terminals and cause the blower to run all the time. This happens with these no model number units.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Split unit system [ 2 Answers ]

How is the split unit of a/c system work,whai is the component of the split unit and what is the troubleshooting of this unit

Split unit 30000 BTU [ 4 Answers ]

I have a 30000 BTU split, the unit runs, but my concern is the accumulator freezes The pipes are cold but not frozen, the condenser makes a high sucking sound, The pressure on the low side is between 6-7 bar but the high side also has the same reading of 6-7 bar, this is not normal. As it should...

A/c split unit [ 1 Answers ]

Hi my a/c split unit will not run, it has two capacitors for the fan units, and following power problems and a possible surg of power back on. The 240 volts are OK on the supplies, but I also have 240 volts at the Nuetrals too, is this correct.

Goodman 3ton split unit Heat will not come on [ 10 Answers ]

After turning up heat, blower will not come on, or the heat. What do I look for or trouble shoot?. thanks


View more questions Search