    malichi61's Avatar
    malichi61 Posts: 1, Reputation: 1
    New Member
     
    #1

    Dec 5, 2007, 06:35 PM
    Gas furnace heating cycle
    I have a 10 yr. old mobile home with a butane furnace. The furnace lights fine. When the burner lights and burns, the blower will come on but won't run a full cycle. It runs and shuts off, then back on and off instead of coming on and running a cycle until thermostat kicks it off. I've put 3 new switches a new gas regulator and thermostat on it. It's dollering me to death and I still have the same problem. I've had a repair man out twice and he just guessing by trying trial and error. Has anyone ever had the same problem?
    wmproop's Avatar
    wmproop Posts: 3,749, Reputation: 91
    Ultra Member
     
    #2

    Dec 5, 2007, 08:39 PM
    Have you cleaned the flame senser?, also where it is mounted to furnace,unscrew and tighten back up to be sure of a good ground,, also check the antisapater,(bad speller) in the thermostat.its a little dial in stat,, but if you have a digital stat you won`t find one, also jumper or tie together the white and red stat wires ,this bypasses the stat to see if furnace work well without the stat,if work OK you might want to make sure all wire to stat are tight,, maybe the stat is bad,,
    wmproop's Avatar
    wmproop Posts: 3,749, Reputation: 91
    Ultra Member
     
    #3

    Dec 5, 2007, 08:40 PM
    Just because the thermostat is new,don`t mean its good
    letmetellu's Avatar
    letmetellu Posts: 3,151, Reputation: 317
    Ultra Member
     
    #4

    Dec 5, 2007, 08:53 PM
    There are several things that can cause this to happen, one of the things that can cause it but is overlooked so often and that is a dirty air conditioning evaporator coil. If the coil is dirty the unit will turn off by way of the limit switch, in a few minutes it will cool and the limit will close again and the unit will come on then the whole things happens again. It will do this three or four times and then the logic board will put it into lock out mode and it will stay that way for several hours. But if you turn off the power to the unit, (like turning off the switch one the furnace) this will reset the logic board and the whole thing will start over again.

    I am not saying that this is you problem, I just know that it does happen and is almost always over looked. Good Luck.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

T-stat heating cycle [ 7 Answers ]

I purchased a Honeywell RTH6300B to replace my current digital T-stat. Everything looked good until I called Honeywell to ask about the heating cycle setting. During the conversation I discovered that this device has a permanent setting of +/- 1 degree F. My current T-stat allows +/- 2 degrees...

Knock in Heating Cycle [ 1 Answers ]

Ea heating cycle, I hear a(one) loud knock in/from the furnace. Can you tell me what this might be and the solution? Thanks,

Dog heating cycle [ 1 Answers ]

How often does a mini dachshund come in heat after her first litter?

Heating Cycle not restarting. [ 6 Answers ]

Hello, it looks like some people have posted similar issues in the past but head to different results or reasons? My problem consists basically of: Set the temperature Heater kicks House heats to desired temp Heater kicks off House cools Heater never kicks on again


View more questions Search