    Fuse in furnace blowing
    My buddy has a payne heat pump system with a payne air handler and every time the heat is turned on at the termostat the fuse blows in the air handler cabinet. The fuse will not blow if emergency heat is turned on or the a/c what is the problem here? I have been working in hvac for six years but not on payne equipment. I hear there is a problem however with the circuit board. Please help!
    NorthernHeat's Avatar
    NorthernHeat Posts: 1,455, Reputation: 132
    Ultra Member
     
    #2

    Dec 17, 2006, 07:54 PM
    High or low voltage fuse? If it is a high amp fuse youmay need to pull the heat bank out and make sure none of the elements have shorted to ground.
    duckman11's Avatar
    duckman11 Posts: 3, Reputation: 1
    New Member
     
    #3

    Dec 17, 2006, 08:04 PM
    Low voltage 5 amp fuse. Fuse Only blows when you turn on heat. He said the board was replaced last year on the outdoor unit.
    T-Top's Avatar
    T-Top Posts: 1,871, Reputation: 100
    Ultra Member
     
    #4

    Dec 17, 2006, 08:24 PM
    If it's a low voltage fuse blowing check at the heat pump. The defrost sensor,low pressure switch or high pressure switch is common to ground out on this unit. They will start to rub on the refrigerant lines short out and blow the low voltage fuse.
    duckman11's Avatar
    duckman11 Posts: 3, Reputation: 1
    New Member
     
    #5

    Dec 17, 2006, 08:52 PM
    Thanks I will look at it tomorrow, I appreciate the help.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Furnace sometimes blowing cold air [ 7 Answers ]

We bought a brand-new house in May 2002. This winter (I don't think it happened last winter) when it got really cold outside, the furnace blew cold air. When it warms up outside, it starts blowing warm again. We had someone come and look at it and he told us it had a 30 degree heat pump?? And when...

92 Honda Accord, A/C Fuse keeps on Blowing out. [ 9 Answers ]

I have a 92 honda Accord EX. The A/C fuse (7.5A) (under the steering wheel) keeps on blowing out. Every time I replace it, it cools the car for 5 minutes and the A/C fuse is blown out again. I am not sure where to start diagnosing the problem. Any suggestions would be highly appreciated. One of...

Comfortmaker Furnace Fan blows in line fuse and will not allow furnace to work [ 1 Answers ]

I have a Comfortmaker Furnace (approximately 1998/99) and the fan will not turn on allow the furnace to heat. When I try to turn the furnace on it blows a 3 amp fuse at the blower motor. I removed the fuse and jumped it and all it will do is make a faint buzzing noise and not turn on. I can...

Furnace blowing cold air [ 3 Answers ]

Ruud oil furnace blowing cold air, fan running constantly

Alternator solenoid valve fuse blowing with 1990 Honda Civic [ 0 Answers ]

A frined (I guess you could cal him that) gave me a 1990 Honda Civic that doensn't run... two problems: one problem is that the fuse to the alternator solenoid valve blows when I turn the key to start thus I can't get the codes from the EUC.. the other one is that there is no fuel getting into the...


View more questions Search