    Furnace not reaching target temp
    My furnace never reaches the target temperature on the thermostat. Even if I increase the temp on the thermostat, the temperature is never met. The current temp is set for 74 degrees, it was 62 this morning? The furnace is a Goodman, the thermostat is digital. I just replaced the thermostat because I thought the old one didn't work. Nothing changed. When I connected the new thermostat, there were several colored wires. I connected all wires, including a red wire into the Rh slot. The Rh/Rc slot had a jumper. Should I have removed the jumper?
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Dec 4, 2007, 10:52 AM
    Leave jumper alone.
    You have another problem besides a thermostat.
    Are your air filters clean?
    Does the blower motor run?
    Is the burner cycling on and off rapidly?
    gba's Avatar
    gba Posts: 7, Reputation: 1
    New Member
     
    #3

    Dec 4, 2007, 11:31 AM
    I just replaced the air filter, is there any others that need to be replaced? The blower motor seems to be running, and the cycle isn't real rapid on/off, it lasts about 15 minutes before shutting off
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #4

    Dec 4, 2007, 01:06 PM
    No other filters that I know of. I guess all of your registers are open?
    Thermostats can have adjustable heat anticipator settings. Look in your install manual to see if there is a section on it listed. You might have to increase that setting.
    Has this furnace worked well before or did you just buy the house?
    gba's Avatar
    gba Posts: 7, Reputation: 1
    New Member
     
    #5

    Dec 4, 2007, 01:48 PM
    Its pretty much always done this, I decided to change the thermostat because it was old and falling off its mounting. I assume all the regesters are open? Is there a certain place I should make sure if the regesters are all open? Air does flow into all the rooms, its just a question of shutting off before the target temp is met? Is there a heat anticipator setting even on digital/programmable thermostats? I don't recall seeing anything in the instructions. Do you think that maybe its restricted ductwork? Any way to fix that?
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #6

    Dec 4, 2007, 01:53 PM
    Usually there is a way to change the heat anticipator setting. What is the brand and model number.
    gba's Avatar
    gba Posts: 7, Reputation: 1
    New Member
     
    #7

    Dec 4, 2007, 02:02 PM
    It's a honeywell, I don't have the model number with me... could it be possible that something on the furnace itself can be adjusted to increase its cycle time?
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #8

    Dec 4, 2007, 02:12 PM
    NO it is adjusted on the thermostat. I will need the complete model number.

    Another possibility is a limit control that has lost it setting/or went out of calibration. Usually these are not adjustable on many furnaces and have to be replaced.
    gba's Avatar
    gba Posts: 7, Reputation: 1
    New Member
     
    #9

    Dec 4, 2007, 02:23 PM
    I can get the model number in an hour...

    As for the limit control, where is it located and is it possible for me to fix it or even know if its lost its setting?

    By the way, you've been a great help... thank you very much...
    gba's Avatar
    gba Posts: 7, Reputation: 1
    New Member
     
    #10

    Dec 4, 2007, 03:31 PM
    The model number of the thermostat is honeywell RTH221
    MEGH2010's Avatar
    MEGH2010 Posts: 3, Reputation: 1
    New Member
     
    #11

    Mar 15, 2008, 09:07 PM
    Quote Originally Posted by hvac1000
    NO it is adjusted on the thermostat. I will need the complete model number.

    Another possibility is a limit control that has lost it setting/or went out of calibration. Usually these are not adjustable on many furnaces and have to be replaced.
    Is the "limit control" on the heater or the thermostat?

    Thanks, Meg
    MEGH2010's Avatar
    MEGH2010 Posts: 3, Reputation: 1
    New Member
     
    #12

    Mar 15, 2008, 09:15 PM
    Quote Originally Posted by hvac1000
    No other filters that I know of. I guess all of your registers are open?
    Thermostats can have adjustable heat anticipator settings. Look in your install manual to see if there is a section on it listed. You might have to increase that setting.
    Has this furnace worked well before or did you just buy the house?
    If the "heat anticipator" was set too low, would you be able to just increase the thermostat setting? Or, would this require that the thermostat be turned off to "reset" and turned back on to a higher temp? Thanks, Meg
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #13

    Mar 15, 2008, 09:46 PM
    See configuration menu 3 on the link below

    http://customer.honeywell.com/techli...69-2060EFS.pdf



    Heating cycles
    Per hour

    • 1: 60 min (steam, gravity)
    • 3: 20 min (hot water, 90%+
    High-efficiency furnace)
    • 5: 12 min (gas or oil)
    • 9: 6.7 min (electric

    Make sure it is still set to 5 for 5 12 minure cycles per hour.

    One other thing you mentioned in on of your posts.

    (((Its pretty much always done this, I decided to change the thermostat because it was old and falling off its mounting. I assume all the regesters are open? Is there a certain place I should make sure if the regesters are all open? Air does flow into all the rooms, its just a question of shutting off before the target temp is met? Is there a heat anticipator setting even on digital/programmable thermostats? I don't recall seeing anything in the instructions. Do you think that maybe its restricted ductwork? Any way to fix that?)))

    You said it has pretty much done this. So this problem was there before the new thermostat?

    There has to be a reason the furnace is turning off before it meets the temperature requirements you set on the thermostat.

    The thermostat controls the call for heat but other items like a defective high limit control, or other controls in the furnace can cause this to happen. I believe your furnace needs to be looked at by a professional especially since this has been doing this for sometime. With out specific meter readings and being able to be there to test it is all guess work here.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Electric furnace won't kick off at desired temp [ 1 Answers ]

I have an electric furnace that is approx. 15 years old. It will work fine, until about 2:00am, then it will not kick off. I have checked the thermostat, & it is kicking back like it is supposed to, but the furnace continues to run. I had this problem, very sporadic last year. Now it is happening...

Goodman furnace cycles but does not reach set temp [ 2 Answers ]

I have a Goodman 70,000 BTU, up flow gas furnace (GMV950704CXA) with a Honeywell (RTH 7500D) thermostat installed, November 2006. The unit worked fine until outside temperature went into the 20s. Unit fires and goes through normal sequence and runs for approximately 7 minutes, then cycles down...

Furnace won't maintain temp - shuts off [ 5 Answers ]

Furnace problem - Turn temp to 70 Furnace runs until 70 degrees Maintains temperature for awhile - probably for a couple of hours At some point it stops maintaining the temperature and keeps kicking on and off. I've watched the thermostat - I'll actually turn the temp up to try to get it to...

Oil furnace kick in and stop when water temp is high [ 2 Answers ]

Good afternoon, My house is heated with an oil furnace providing heat to a hot water baseboard system. For the last little while, I noticed the burner kicking-in for a few second when the thermostat send the signal (close the circuit) and stop with a second or two. When it does that the water...

Carier furnace shuts off before reaching temp [ 2 Answers ]

I have a carier weathermaker furnace that shuts off before reaching temp. any idea what could be the problem.


View more questions Search