Left for the weekend and when I came home my Goodman furnace fan would not cut off. The batteries had died in my Hunter thermostat. I've replaced the batteries and it still will not cut off. What would cause the fan to stay on?

1 Answer
hvac1000's Avatar
hvac1000 Posts: 14,539, Reputation: 2381
Heating & Air Conditioning Expert
 
#2

Mar 23, 2008, 09:55 PM


System went out on high limit causing the control board to keep the fan running.
Bad fan controler
Something wrong with the thermostat causing the call for fan all the time.

Turn off main breaker to furnace then reactivate and see if that resets the system.
Check air filters and replace if necessary.
Helpful

Not your question? Ask your question View similar questions

 
Thread Tools Search this Thread
Search this Thread:

Advanced Search

Add your answer here.

Remove Text Formatting

Undo
Redo
 
Decrease Size
Increase Size
Bold
Italic
Underline
Align Left
Align Center
Align Right
Ordered List
Unordered List
Decrease Indent
Increase Indent
Insert Email Link
Wrap [QUOTE] tags around selected text
Wrap [CODE] tags around selected text
Wrap [HTML] tags around selected text
Wrap [PHP] tags around selected text
Wrap [YOUTUBE] tags around selected text
Notification Type:



Check out some similar questions!

Wiring a furnace thermostat to manually operate the furnace fan [ 2 Answers ]

I have two wires connected to my furnace thermostat. There is a place labeled G on the thermostat. Can I simply run a wire from the G terminal on my thermostat to the terminal labeled G on my furnace fan relay to operate the fan separately?

Honda Accord fan that won't cut off [ 1 Answers ]

Hello i have a 96 Honda Accord and the fan won't cut off. Hondas are not my speciality so and the only thing i can think of is to disconnect the fan but then the car will run hot so if someone can start me off with the trouble shuting.

Wiring inline duct fan to furnace fan goodman gmp100-4 [ 2 Answers ]

How do I wire my inline duct fan to my Goodman model gmp100-4 gas furnace fan so that the inline duct fan comes on and off when the furnace fan does? I understand that I need a relay from the inline duct fan but don't know where to connect the relay to the furnace.

Comfortmaker Furnace Fan blows in line fuse and will not allow furnace to work [ 1 Answers ]

I have a Comfortmaker Furnace (approximately 1998/99) and the fan will not turn on allow the furnace to heat. When I try to turn the furnace on it blows a 3 amp fuse at the blower motor. I removed the fuse and jumped it and all it will do is make a faint buzzing noise and not turn on. I can...

A/C airhandler fan won't cut on, intermittingly [ 2 Answers ]

A/C compressor on heat pump works fine, but occassionally it runs and the airhandler fan does not cut on, causing outside unit to freeze. If I turn thermo switch off and back on, it usually corrects the problem and it works fine until it fails to cut on again, maybe 5 minutes, or maybe a week. If...


View more Heating & Air Conditioning questions Search