Ask Experts Questions for FREE Help !
Ask
    whm249's Avatar
    whm249 Posts: 1, Reputation: 1
    New Member
     
    #1

    Jan 21, 2010, 03:39 PM
    Furnace fan and igniter come on but furnace does not light
    My furnace is not lighting (I believe it is a Day and Night). When I turn up the thermostat, the venting fan motor comes on as usual.. followed shortly by the igniter (I can hear the "snap snap.." of the igniter), but after that, burner never comes on, so the blower never comes on etc. It has been somwhat intermittent. The other day it seem like it took a long time for the blower to come on, but just as I was about to go out in the garage to check what might be going on with the furnace it came on, so I just assumed it was my perception that it took a long time. Then last night it did not come on at all. Just the vent fan and igniter clicking for 5 minutes without the burner ever lighting. I tried it later in the evening however, and it did light up and blow warm.. but then did not light again this morning.

    I need to call someone out, but wanted to know what to expect the problem might be. Would the igniter make the snapping sound if it was not working? Could it be the gas valve. Thermocouple (is there even a thermocouple in this type of system?). Does this sound like it might be a fairly expensive problem to fix?

    I just don't want some repair person to give me some line to boost the cost of the repair.
    T-Top's Avatar
    T-Top Posts: 1,871, Reputation: 100
    Ultra Member
     
    #2

    Jan 21, 2010, 07:20 PM

    Sound like you have a dirty pilot assembly. If the gas can't hit the spark its not going to light. A restriction on the pilot hood or orifice will make this happen. Not to rule out a bad gas valve(pilot side not opening all the time). It can cost as little as a service call or around $200 for the gas valve plus labor.

Not your question? Ask your question View similar questions

 

Add your answer here.


Check out some similar questions!

Carrier furnace igniter doesn't glow [ 3 Answers ]

I have a Carrier furnace 58PAV070-12 about 15 yrs old. When I turn on the heat, everything seems to try to light the furnace but the ignition coil does NOT glow red. The system tries 3 times and then locks out and then it blinks code 34. Is there some type of reset I am missing? I have unplugged it...

Coleman Evcon Furnace igniter [ 1 Answers ]

We have had to replace the igniter in our furnace at least 4 times in a little over a year. What could be making them burn out? We had two go out in just one weeks time! This was 12-25-07. We had a new one installed late April of this year so it wasn't used that much. We turned the furnace on last...

Fan goes on, furnace doesn't light [ 1 Answers ]

I have a Model 7970-656/D Coleman-Evcon gas heater, it has worked fine for the last few years, now when the thermostsat is turned up the fan goes on but the furnace doesn't fire up. I'm having a hard time finding the right parts ( no model #'s ) to see if it might be the HSI. Any help?

Igniter will not light furnace [ 3 Answers ]

Carrier gas furnace will try to start, but igniter does not light furnace. Red light in window flashes -is thiis the "code" for the numeric list on the attached plate?


View more questions Search