Question
 
 
#1  
Old May 18, 2004, 02:09 PM
mhanks
New Member
mhanks is offline
 
Join Date: May 2004
Location:
Posts: 2
mhanks See this member's comment history on his/her Profile page.
Send a message via ICQ to mhanks
Furnace fan

I have a forced-air gas furnace w/o AC and a simple dial-type heat-only thermostat.  How do I change my system so that I can manually operate the furnace fan when not calling for heat?

Merlyn

Reply With Quote
 
     

Answers
 
 
Old May 18, 2004, 03:25 PM   #2  
Über Member
labman is offline
 
Join Date: Feb 2003
Location: Northern US
Posts: 10,646
labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.labman See this member's comment history on his/her Profile page.
Re: Furnace fan

This will be much easier with some furnaces than others. Some furnace controls have a contact, usually a screw, which will operate the furnace fan when ever energized. Pull your thermostat off the wall and look at the wires. Usually they have a bundle of wires with red hot to thermostat, green blower, white heat, yellow air, and blue common. If your thermostat has all the wires, but only the red and white connected to anything, try touching the green to the red, they are only 25 volts. If the blower immediately comes on, it is a simple job from there. Just buy any kind of a cheap little switch, and connect the red wire to it and the current contact of the red, and the green to the other contact. The only thing is, make sure the switch is a maintained contact switch, and not a momentary switch that shuts off as soon as you let go. You can also buy thermostats that have a fan switch built into them. Note, somebody may have cut corners and switched the red and white wires.

If you only have the red and white wires, go to the furnace. See if there is a contact marked G near where the red and white connect. Still a fairly simple job. Buy some green bell or hook up wire, likely 26 gauge or a smaller number (bigger wire) will do. Run it from the G contact at the furnace to a switch as I described above. If you ever think you may instal air, maybe you should buy the regular thermostat wire and instal it now, just leave the blue and yellow disconnected.

If you can't find any contacts in the furnace anywhere marked G, it may not be a simple job. Some where, there is a relay controlling the blower, perhaps one for each different speed of the motor. It should have a blue wire going back to the transformer and the white wire connecting to it through a delay timer or temperature switch. They keep the blower from starting up until the burner has a chance to warm the air. Running a green wire from it back to a switch at the thermostat might work. It might also feed back to the gas valve, turning it on. You may need to call on experienced help to make that work.

Blowers do not draw that much power. You might be able to run a wire from the 115 volt feed to the furnace through a switch to the blower. Connect black to black through the switch, and white to white. The blower motor should have a plate telling the amperage it draws. Make sure the switch and wires are rated for at least that much at 115 volts, and the higher value if 2 are given, 5/10 amps. If you want the switch in the house away from the furnace, you must use suitable wire, NM or BX the same as the rest of the wire in the house. Again, you may need to call on experienced help to make that work.
  Reply With Quote
 
     
 
 
Old May 19, 2004, 02:37 PM   #3  
New Member
mhanks is offline
 
Join Date: May 2004
Location:
Posts: 2
mhanks See this member's comment history on his/her Profile page.
Send a message via ICQ to mhanks
Re: Furnace fan

Thanks, Labman, for such a complete and concise instruction. I 'll give it a try.

Merlyn
  Reply With Quote
 
     

Your Answer
Email me when someone replies to my answer
Join Login





Thread Tools Search this Thread
Search this Thread:

Advanced Search
Display Modes

 
Similar Sponsors


Thread Tools
Show Printable Version Show Printable Version
Email this Page Email this Page

Similar Threads
AC furnace fan delay
(0 replies)
gas furnace
(1 replies)
gas furnace
(14 replies)
Furnace
(3 replies)
new furnace
(9 replies)

Search this Thread

Advanced Search

Bookmarks

Sponsors



Copyright ©2003 - 2009, Ask Me Help Desk.
All times are GMT -8. The time now is 02:52 AM.