Question
 
 
#1  
Old Jan 12, 2008, 09:29 AM
izick
New Member
izick is offline
 
Join Date: Jan 2008
Posts: 1
izick See this member's comment history on his/her Profile page.
funcace not running

i have a Intertherm mac1265 oil funrace it will run for 10-20min then kicks the reset i have 200+gals in tank but will not reach set temp keeps popping reset thank you paul

Reply With Quote
 
     

Answers
 
 
Old Jan 12, 2008, 03:12 PM   #2  
Junior Member
Frdbrkl is offline
 
Join Date: Jan 2008
Location: Metro Washington DC area
Posts: 94
Frdbrkl See this member's comment history on his/her Profile page.
Have the nozzle and filter changed regularly (once a year should suffice) and clean the photocell.

Turn off the power to the furnace. On top of the burner assembly is a large black box-the transformer-which is hinged on one side. Loosen the screw(s) on the opposing side, and swing the transformer up and over. Follow the yellow wires from the reset control into the burner box and underneath the transfomer-torwards the back is the photocell or Cad Cell. It is usually held in place by a clip that just slides forward to remove it-clip, cell, and all.

Clean the cad cell with a clean dry cotton cloth, reinstall, making sure to tighten the screws securely-but don't strip them. Cycle the furnace. If you've changed the oil filter, nozzle, cleaned the cad cell, you may need a new cad cell. Repeat process, but this time pull Cad Cell out of holder/clip (it has 2 small round male pins on the end of it). Unfortunately I don't know where you could purchase one outside of Graingers.
  Reply With Quote
 
     
 
 
Old Feb 11, 2008, 09:49 AM   #3  
New Member
kingshive is offline
 
Join Date: Feb 2008
Posts: 4
kingshive See this member's comment history on his/her Profile page.
Quote:
Originally Posted by Frdbrkl
Have the nozzle and filter changed regularly (once a year should suffice) and clean the photocell.

Turn off the power to the furnace. On top of the burner assembly is a large black box-the transformer-which is hinged on one side. Loosen the screw(s) on the opposing side, and swing the transformer up and over. Follow the yellow wires from the reset control into the burner box and underneath the transfomer-torwards the back is the photocell or Cad Cell. It is usually held in place by a clip that just slides forward to remove it-clip, cell, and all.

Clean the cad cell with a clean dry cotton cloth, reinstall, making sure to tighten the screws securely-but don't strip them. Cycle the furnace. If you've changed the oil filter, nozzle, cleaned the cad cell, you may need a new cad cell. Repeat process, but this time pull Cad Cell out of holder/clip (it has 2 small round male pins on the end of it). Unfortunately I don't know where you could purchase one outside of Graingers.
Don't worry so much about the eye itself, worry about what is down the burner tube causing the eye to lose sight of the flame.

More info is needed before we can find the solution. Is there any sputtering or smell, post-burn? Does the house get warm? You're sure it's tripping the safety reset? No-one has touched any other control on the unit?
  Reply With Quote
 
     


Thread Tools
Display Modes

 
Similar Sponsors

Similar Threads
Question Asker Forum Answers Last Post
running away TakeMeAway7629 Teens 9 Nov 26, 2007 10:19 AM
running away joeysgirl Missing Persons 12 May 13, 2007 09:07 PM
bath tub shower spout & head running water running at same time poppi g Plumbing 1 Jan 22, 2007 05:02 AM
am i running? Skell Relationships 11 Jun 7, 2006 03:03 PM
What about running... Flickit Plumbing 2 Jun 3, 2005 05:12 AM




Copyright ©2003 - 2007, Ask Me Help Desk.
All times are GMT -8. The time now is 04:25 PM.