Ask Experts Questions for FREE Help !
Ask
    Pedro Arango's Avatar
    Pedro Arango Posts: 2, Reputation: 1
    New Member
     
    #1

    Feb 14, 2009, 09:42 AM
    Furnace burner keeps working even if the blower is not working
    My gas furnace (Trane XL80) this morning started to smell like plastic was burning from the registers, I went to check the furnace and noticed that the blower wasn't working so I turned the breaker off. My question is, should the burner had to turned off if the blower wasn't working for some time?
    KC13's Avatar
    KC13 Posts: 2,556, Reputation: 99
    Ultra Member
     
    #2

    Feb 14, 2009, 09:53 AM
    Sounds like a failed blower motor. Eventually the high-limit control would have shut down the burners, but not until the limit temperature was reached (typically 160-220 degrees at the limit control location). Try this: Set thermostat system selector switch to "off" and fan selector to "on". Does blower run? If so, allow it to run for a while, see if the motor overheats and shuts down.
    Pedro Arango's Avatar
    Pedro Arango Posts: 2, Reputation: 1
    New Member
     
    #3

    Feb 14, 2009, 10:15 AM

    The blower did not work when I did the changes on the thermostat.

    I will change the blower and capacitor.

    Thanks for the help.
    KC13's Avatar
    KC13 Posts: 2,556, Reputation: 99
    Ultra Member
     
    #4

    Feb 14, 2009, 10:19 AM
    Your welcome. P.S. Carefully feel the motor. If it's really hot to the touch, it has overheated and activated the internal thermal protection device. That would explain why it doesn't run now.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Heat,Rheem Furnace blower not working [ 6 Answers ]

HELLO, JUST CAME HOME IN NJ TO FIND HEAT NOT WORKING. FURNACE IS A RHEEM CLASSIC 90, MODEL#rcba-3765gg21x1. Have power to unit, breaker is on, when I depress covers interlock switch, LEDs light briefly & I can hear what sounds like a burner starting. Blower does not come on. Verified Thermostat...

Blower not working & burner goes off [ 12 Answers ]

I have a gas furnace that has elec ignition, once that gets real red, burner comes on for about 3-4 minuetes and then turns off? Any Ideas?? Blower at bottom of furnace never blows, but small blower up top comes on before burner lights and after it goes out it stays on for about 4-5 minuetes?...

Furnace working, blower not [ 7 Answers ]

Comfortmaker furnace. Heat comes on and goes through normal cycle. Blower will not engage. Is there a reset or is that to easy?

Central AC with gas furnace blower not working [ 3 Answers ]

The house was getting hot so I checked the thermostat and discovered there was no air coming out of the vents. The outside unit comes on but no noise from up in the attic. I had no problems earlier in the day. The fan doesn't come on in the auto or on position.:confused:


View more questions Search