    Furnace blower will not come on unless I spin the fan blades.
    I have an old GE electric furnace. When I try to turn on the air conditioning the outside fan works but the furnace does not come on. I went downstairs and I could hear that power was reaching the furnace so I turned off the power at the circuit breaker, and then turned it back on and nothing happened. I turned off the circuit breaker again to check and see if the fan blades were stuck and I was able to spin them freely. I decided to try spinning the blades and turning the circuit breaker back on and it worked, however it shut off again in about thirty minutes. I tried testing the heat and it worked under the same conditions and for the same length of time. :confused:
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #2

    Aug 10, 2009, 10:03 PM
    It could just be the fan motor capacitor is defective but it is also possible the motor itself is going bad.
    kayzee's Avatar
    kayzee Posts: 3, Reputation: 1
    New Member
     
    #3

    Aug 11, 2009, 07:20 PM

    I have ordered a new capacitor, will report back once I have installed it. Thanks for the information.
    kayzee's Avatar
    kayzee Posts: 3, Reputation: 1
    New Member
     
    #4

    Aug 14, 2009, 02:36 PM

    I just replaced the capacitor and it worked! Thanks again!
    hvac1000's Avatar
    hvac1000 Posts: 14,540, Reputation: 435
    Heating & Air Conditioning Expert
     
    #5

    Aug 14, 2009, 02:40 PM
    Glad you got it running.

Not your question? Ask your question View similar questions

 

Question Tools Search this Question
Search this Question:

Advanced Search

Add your answer here.


Check out some similar questions!

Furnace Blower Motor Runs Constantly & Furnace or AC Won't Run [ 2 Answers ]

I have an Armstrong forced air (induced draft) natural gas furnace with central AC (made around 1990 -- Model: EG6H80DC14-1, Serial: A18315MNA). I had a problem at the end of the heating season where the blower motor would run continuously (even when the thermostat is turned to "off"). I thought...

Furnace ignites but blower won't start till furnace shuts down. [ 7 Answers ]

(Nordyne/Miller G3RA)-I have a furnace HSI(glow plug) that will ignite and burn until it gets too hot and shuts down. As soon as the furnace shuts down the blower starts to circulate air. The blower circulating air cools the furnace and it reignites.Shortly after the furnace ignites the blower...

Furnace blower won't run [ 1 Answers ]

I have a 1994 Conquest furnace with a Honeywell circuit board. The exhust fan will run and then the burners will start but when the circuit board "clicks", the blower won't run. I noticed on the back of the board a burned spot at one of the solder points. I referanced the board number, ST9101A...


View more questions Search